Mounting and start-up
Vento
®
II
1.0
11 / 74
Bl k
e
d
2. Thread the battery connection cable (6) through the
opening (3).
3. Secure the battery cable plug (4) to the holder (5).
3.3 Install the electronic linkage control (EHR)
1. Secure the sensor in the joint area of the lower
link.
2. Secure the magnetic encoder to the lower link.
3. Set the position of the sensor and the magnetic
encoder.
Maximum distance 8 mm.
Advice
Please note that the contact
surfaces (1) of the sensor
are only located on the left
and right sides.
Sensor inactive
The sensor must not be within range of the magnetic encoder.
Sensor active
The sensor must be within range of the magnetic encoder.
Signal from linkage control
The "active" signal can be output during raising or lowering. Check the correct setting
see "Electronic linkage control
.
Содержание Vento II
Страница 73: ...Vento II 1 0 73 74 ...