9
Prior
To assign Daylight Load binding to the previous load, choose
PRIOR
. This is similar to
NEXT
, but chooses the previous load.
This function behaves the same for all Operation Modes.
Done
When you have completed all load bindings, choose
DONE
.
This function behaves the same for all Operation Modes.
Bi-Level Load Assignment
To do load binding the load needs to be assigned as a Daylight
Load by selecting “Yes”.
Next
,
Prior
and
Done
function the
same as for Switched and Dimmed.
L o a d
1
D a y l i g h t L o a d :
< N o >
N E X T P R I O R D O N E
Z o n e S e t u p L M L S - 4 0 0
B i - L e v e l
L o a d
1
D a y l i g h t L o a d :
< Ye s >
O N W h e n :
< M e d & M a x >
N E X T P R I O R D O N E
Press Left/Right
arrow to choose
<Med & Max> or <Max>
Z o n e S e t u p L M L S - 4 0 0
B i - L e v e l
Press Left/Right
arrow to choose
<Yes> or <No>
For Load 1:
If <Yes> is selected,
ON When
appears
after scrolling down.
Tri-Level Load Assignment
To do load binding the load needs to be assigned as a Daylight
Load by selecting “Yes”.
L o a d
1
D a y l i g h t L o a d :
< N o >
N E X T P R I O R D O N E
L o a d
1
D a y l i g h t L o a d :
< Ye s >
O N W h e n :
< L o w & M a x >
N E X T P R I O R D O N E
Z o n e S e t u p L M L S - 4 0 0
Tr i - L e v e l
Z o n e S e t u p L M L S - 4 0 0
Tr i - L e v e l
Press Left/Right
arrow to choose
<Yes> or <No>
For Load 1:
Press Left/Right
arrow to choose
<Hi & Max> or
<Low & Max>
If <Yes> is selected,
ON When
appears
after scrolling down
Next
,
Prior
and
Done
function the same as for Switched and
Dimmed.
Zone Setup (LMLS-500 Only)
Selecting the Operation Mode
Zone Setup allows you to select the number of zones, change
the operation mode of a zone, specify if a selected load is to be
controlled by Daylighting and to bind loads to the LMLS-500.
For each zone, the Operating Mode types are the same as for
the LMLS-400 and LMLS-600. See
Z o n e S e t u p L M L S - 5 0 0
N u m b e r o f Z o n e s
< 3 >
C h o o s e t h e n u m b e r o f
D a y l i g h t i n g Z o n e s
Press
Select
L M L S - 5 0 0 0 2 9 3 7 2 4 9 0 9
Z o n e S e t u p
C a l i b r a t i o n
Z o n e S e t t i n g s
A d v a n c e d S e t t i n g s
C o n t r o l M o d e
Z o n e S e t u p L M L S - 5 0 0
N u m b e r o f Z o n e s
< 3 >
C O N T I N U E
Press Left/Right arrow to
select the number of Zones
(1, 2, or 3)
P o i n t t o A n y I R
e n a b l e d d e v i c e o n
t h e n e t w o r k
P r e s s ‘ S e l e c t ’
C h o o s e t h e n u m b e r o f
D a y l i g h t i n g Z o n e s
Z o n e S e t u p L M L S - 5 0 0
Z o n e 1 :
< B i - L e v e l >
Z o n e 2 : < S w i t c h e d >
Z o n e 3 : < Tr i - L e v e l >
C O N T I N U E
P i c k a c o n t r o l t y p e
f o r A L L Z o n e s
Z o n e S e t u p L M L S - 5 0 0
B i - L e v e l
N E X T P R I O R D O N E
Point and
Press Select
C O N T I N U E
Press
Select
Choose
CONTINUE
Press Left/Right arrow to choose the
desired operation mode for each Zone:
<Switched>, <Bi-Level>,
<Tri-Level> or <Dimmed>
Point and
Press Select
P o i n t t o a n y I R
e n a b l e d d e v i c e o n
t h e N e t w o r k
P r e s s ‘ S e l e c t ’
Switched and Dimmed Load Assignment
The load binding process for Switched loads and Dimmed
loads is the same as it is for the LMLS-400 and LMLS-600.
However, instead of the
Daylight Load
parameter used when
programming those models, the LMLS-500 screen has a
Zone
parameter. By default it is set to “None”. You must select a Zone
for the load.
L o a d :
1
Z o n e :
< N o n e >
N E X T P R I O R D O N E
Press Left/Right
arrow to select
the Zone
Depending on the Operation Mode,
the screen display will be Switched
or Dimmed
Load 1:
Z o n e S e t u p L M L S - 5 0 0
S w i t c h e d
Once the zone is assigned, select
NEXT
to continue to the next
Load.
Next
,
Prior
and
Done
function the same as they do for
the LMLS-400. See the previous page for details.
Bi-Level and Tr-Level Load Assignment
Once again this load binding is the same as for the LMLS-400,
but the
Zone
parameter is displayed instead of
Daylight Load
.
You must select a Zone for the load.
Load 1: Press Left/Right
arrow to select
the Zone
Z o n e S e t u p L M L S - 5 0 0
B i - L e v e l
N E X T P R I O R D O N E
L o a d :
1
Z o n e :
< N o n e >
L o a d
1
D a y l i g h t L o a d : < Ye s >
O N W h e n :
< M a x >
N E X T P R I O R D O N E
Press Left/Right
arrow to choose
a specific value
Z o n e S e t u p L M L S - 4 0 0
B i - L e v e l
If a Zone is selected,
ON When
appears after scrolling down.
Once the zone is assigned, select
NEXT
to continue to the next
Load.
Next
,
Prior
and
Done
function the same as they do for
the LMLS-400. See the previous section for details.