LOCK
EP
WEP
Cable type
2 x 1.0 mm
2
Max distance ≤ 10 m
EP/WEP
LOCK
L-
Cable type 2 x 1.0 mm
2
Max distance ≤ 20 m
EP/WEP
LOCK
L-
L+
ADAPTER
15 V / 2 A
323015
Door lock release
GND
Power
GND
-L+
L- -L+
If the current required for the door lock is more than 1A (DC12 V), the use of an additional power supply is required instead of
obtaining power from the EP. The connection is shown below:
The door lock receives power from
an additional power supply, without
absorbing any current from the EP.
In some cases, other types of door
locks may be used for EPs or main EP.
recommended rJ45
connecTor
The actual working environment may
be damp or hot, which can cause
inferior RJ45 connectors to rust.
Lock type and distance limits
We recommend that Legrand/
Ortronics connectors are used
(see specific catalogue).
No need of power for door lock during stand-b, Door lock releaseVoltage: DC12 V, Door lock releaseCurrent: ≤1 A, Time
needed to release the lock (output voltage to release the lock) : ≤100 ms
The types of door locks below
are also recommended
(shows diagram as figure 1).
The main characteristic recommended
for door locks are below.
Need power for lock in stand-by.
Stand-by Voltage: DC12.
Maximum stand-by Current: ≤ 0.3 A.
Door lock release method: Stop
powering the door lock.
Time needed to release the lock:
Adjustable.
55
GUIDE
D45 SyStEm
WWW.LEGRAND.COM
Содержание D45 SYSTEM
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 9: ...GENERAL FEATURES...
Страница 36: ......
Страница 37: ...GENERAL RULES FOR INSTALLATION...
Страница 82: ......
Страница 83: ...WIRING DIAGRAMS...
Страница 102: ......
Страница 103: ...WIRING DIAGRAMS VARIANTS...
Страница 116: ......
Страница 117: ...CATALOGUE...
Страница 122: ......
Страница 123: ...TECHNICAL SHEETS...