322010
F
F
U
U
B
B
R
R
F
F
U
U
B
B
R
R
Digital colour entrance panel
Mode 5 and Mode 6: When the building number plus unit number (building number and
unit number are coded separately) plus floor number plus room number is not above 9
digits, one of them can be selected. Take Room 1 5th floor, Unit 2 of Building 101 for
example, the riser number will be 101-02-0501.
Mode 5: 8888-8888
Mode 6: 8888-88A
BACkBone eP oR MAin eP
Mode 5: 888-88-8888
888 Building number
88 Unit number
88 Floor number
88 Room number
Mode 6: 888-88-88A
888 Building number
88 Unit number
88 Floor number
A Room number
Mode 7 and Mode 8: When there are several zones in one project and we need the zone number for a call, we
can select one of them. Take Room 1 5/F Unit 2 Building 101 of Zone 2 for example, which can be coded at
02-101-02-0501.
Mode 7: 88-888-88-8888
Mode 8: 88-888-88-88A
BACkBone eP oR MAin eP
Mode 7: 88-888-88-8888
88 Zone number
888 Building number
88 Unit number
88 Floor number
88 Room number
Mode 8: 88-888-88-88A
88 Zone number
888 Building number
88 Unit number
88 Floor number
A Room number
5
.
Select 5 to complete entrance panel configuration parameters setting.
As per the prompt on the display interface, we can set the address of the entrance panel,
the floor number of the said riser and the maximum number of handset installed on each
floor of the riser. We can also set the address of the gate in relation to the Switchboard.
When we come to the setting interface, the configuration parameters of the current
entrance panel will appear. To make changes, enter the desired number in serial order.
After entering the 8 digit number , just press # to confirm.
Note: This setting is only valid when the entrance panel does not use the parameter
of the configurator. For example, a certain place has been configured of its resistance,
and this setting shall be invalid.
6.
Select 6 to setup language: you can setup english or other languages.
7.
Select 7 to setup pulse width for unlock. 1 to 99 seconds can be set for lock opening
pulse.
8.
Select 8 to set the password door lock release function. As per the prompt on the
display, we can enable or disable the function to open the door lock by password.
When we disable this function, the menu item “7 to edit the lock-open password”
shall not be on display, and therefore cannot be edited.
9.
Select 9 to complete the relevant settings of the password door lock release
function. There are 3 available options :
- set the door lock release password
. Press 1 key and enter your desired group
number and the new password. On entering the group number, if password for
the group already exist, it will be replaced by the new one. Press * key to exit and
return to the last operation.
- Delete the door lock release passwords one by one
. Press 2 key and enter the
group number you want to delete. Press # key to delete the password.
- Delete all the door lock release passwords
. Press 3 key and a prompt window
will appear asking you if you want to delete all the door lock release passwords
or not. Press * key to exit and the # key to delete all the passwords.
BT00466-b-en
30/05/2013
Содержание D45 SYSTEM
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 9: ...GENERAL FEATURES...
Страница 36: ......
Страница 37: ...GENERAL RULES FOR INSTALLATION...
Страница 82: ......
Страница 83: ...WIRING DIAGRAMS...
Страница 102: ......
Страница 103: ...WIRING DIAGRAMS VARIANTS...
Страница 116: ......
Страница 117: ...CATALOGUE...
Страница 122: ......
Страница 123: ...TECHNICAL SHEETS...