
N
N
N CF4 CF5 CF6 CF7
N
N
N
FF
min
FF
min
#I
#I
0
0
0
0
1
2
5
CF8 CF9 CF10CF11 TYP ASR M
LE
FF
max
FF
max
TYP ASR M
LE
0
1
6
3
2
1
1
0
Example (C):
If necessary enable the smart
power function, no need for the
power management function (if no
management function, the power
supply address does not need
to be set), the range of handset
addresses managed by the power
supply is 125-163.
Without alarm, it means that the
current of alarm sensor is 0 mA. The
system used Mode 3 configuration.
The power supply configuration
should be as follows:
poSition
Mode 1
Value for
configurator
reMarkS
CF1
N
0
CF2
N
0
CF3
N
0
CF4
FF Min
0
CF5
FF Min
1
CF6
#II
2
CF7
#II
5
CF8
FF Max
0
CF9
FF Max
1
CF10
CF10
6
CF11
CF11
3
CF12
Type
2
CF13
ASR
1
CF14
M
1
CF15
LE
0
C
53
GUIDE
D45 SyStEm
WWW.LEGRAND.COM
Содержание D45 SYSTEM
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 9: ...GENERAL FEATURES...
Страница 36: ......
Страница 37: ...GENERAL RULES FOR INSTALLATION...
Страница 82: ......
Страница 83: ...WIRING DIAGRAMS...
Страница 102: ......
Страница 103: ...WIRING DIAGRAMS VARIANTS...
Страница 116: ......
Страница 117: ...CATALOGUE...
Страница 122: ......
Страница 123: ...TECHNICAL SHEETS...