D45 System
Description
System expansion interface
D45 System interface device used to extend the riser system when there are more than
the limit of 400 handsets on the riser. The interface allow to increase this limit to 800
handsets. Device is also used to adjust video gains and improve video transmission
quality on long distances. DIN RAIL installation.
Technical data
Power supply:
30 Vdc
Stand by current absorption:
≤ 50 mA @ 30 V
Max. operating current absorption: ≤ 80 mA @ 30 V
Stand by power consumption :
1.5 W
Operating power consumption :
2.4 W
Operating temperature:
(-10)-(+40)°C
Dimensional data
Legend
1.
Serial port interface for device firmware update
2.
Video gain setting DIP SWITCH
3.
RJ45 SUB SYSTEM input connector - connect to floor shunt
4.
RJ45 SUB SYSTEM output connector - connect to floor shunt
5.
Power supply input connector (30 V)
6.
Power supply LED indicator
Front view
Video gain setting
DIP switch setting instruction
Distance
1
2
3
4
COlOUr SIgNAl
0 – 300 m
OFF
OFF
OFF
OFF
300 – 700 m
ON
OFF
OFF
OFF
700 – 1000 m
ON
ON
OFF
OFF
B/W SIgNAl
1000 –1500 m
ON
ON
ON
OFF
1500 – 2000 m
ON
ON
ON
ON
BT00465-b-en
13/05/2013
Содержание D45 SYSTEM
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 9: ...GENERAL FEATURES...
Страница 36: ......
Страница 37: ...GENERAL RULES FOR INSTALLATION...
Страница 82: ......
Страница 83: ...WIRING DIAGRAMS...
Страница 102: ......
Страница 103: ...WIRING DIAGRAMS VARIANTS...
Страница 116: ......
Страница 117: ...CATALOGUE...
Страница 122: ......
Страница 123: ...TECHNICAL SHEETS...