189
322050
Colour 7” handsfree indoor handset
Two different device configuration ways available:
WAY 1)
Configuration settings by device keyboard
WAY 2)
Configuration settings by inserting phisical configurators
Configuration settings by device keyboard - WAY 1 :
INSTAllATION SETTINgS OPErATION lIST TABlE
SETUP
OPErATION CODE AND
lIghT STATUS
NExT
OPErATION
MEANINg AND INFOrMATION FOr ThE OPErATION
rEMArk
Set room number for
handset
11#
8 alarm lights and message light off
“FFII#”
correct parameter input: 1 long tone
Default room number: 101
wrong parameter input: 3 short tones
*
return to main menu of installation setup, 1 short tone
other
unsuccessful operation: 3 short tone
Set maximum
apartments quantity
per floor in a riser
12#
8 alarm lights and message light off
“II#” or “I#”
correct parameter input: 1 long tone
Range:1-99
Default:4; it can be set only when
there is no setting for hardware
wrong parameter input: 3 short tones
*
return to main menu of installation setup, 1 short tone
other
unsuccessful operation: 3 short tones
Set external SOS to be
always on or always off
15#
message light will indicate status of
this setting item
1
SOS external switch or pushbutton always
open (NO): message light on, 1 long tone
Default: always
open
0
SOS external switch or pushbutton always close (NC): message light off, 1 long tone
*
return to main menu of installation setup, 1 short tone
other
unsuccessful operation: 3 short tones
Enable and disable
function of monitoring
Small EP
17#
message light will indicate status of
this setting item
1
enable: handset can monitor Small EP: message light on, 1 long tone
Default: cannot monitor Small EP. This
function is available only when the
function is set as Small EP function.
0
Shielded: handset can not monitor Small EP: message light off, 1 long tone
*
return to main menu of installation setting, 1 short tone
other
unsuccessful operation: 3 short tones
Return all the
parameters to default
value
19#
message light will indicate status of
this setting item
1
Get all the default parameters: message light on, 1 long tone
0
Do not get all the default parameters: message light off, 1 long tone
*
return to main menu of installation setup, 1 short tone
other
unsuccessful operation: 3 short tones
Enable and disable
sensors
21#
Message light is off. 8 alarm lights
will indicate status of each alarm
zone
1#
1
1 alarm zone with sensor: LED 1 on, a long tone.
Default: (all) without sensor
0
1 alarm zone without sensor: LED 1 off, a long tone.
*
return to previous menu, 1 short tone
other
Ineffective operation: 3 short tones
…
…
8#
1
8 alarm zone with sensor: LED 8 on, a long tone.
0
8 alarm zone without sensor: LED 8 off, a long tone.
*
return to previous menu, 1 short tone
other
unsuccessful operation: 3 short tones
*
return to main menu of installation setting, 1 short tone
other
unsuccessful operation: 3 short tones
Set NO and NC type of
sensors
22#
8 alarm lights will indicate status of
each alarm zone.
1#
1
always open (NO) sensor for alarm area 1: LED 1 on, 1 long tone
Default: sensors for 8 alarm zones are
always open (NO).
0
always close (NC) sensor for alarm area 1: LED 1 off, 1 long tone
*
return to previous menu, 1 short tone
other
unsuccessful operation: 3 short tones
…
…
8#
1
always open (NO) sensor for alarm area 8: LED 8 on, 1 long tone
0
always close (NC) sensor for alarm area 8: LED 8 off, 1 long tone
*
return to previous menu, 1 short tone
other
unsuccessful operation: 3 short tones
*
return to main menu of installation setup, 1 short tone
other
unsuccessful operation: 3 short tones
BT00472-b-en
03/06/2013
Содержание D45 SYSTEM
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 9: ...GENERAL FEATURES...
Страница 36: ......
Страница 37: ...GENERAL RULES FOR INSTALLATION...
Страница 82: ......
Страница 83: ...WIRING DIAGRAMS...
Страница 102: ......
Страница 103: ...WIRING DIAGRAMS VARIANTS...
Страница 116: ......
Страница 117: ...CATALOGUE...
Страница 122: ......
Страница 123: ...TECHNICAL SHEETS...