N N #F #F #I #I
0 5 2 5 0 8
GENERAL RULES FOR INSTALLATION
If configurator or keyboard
configuration is selected for the
main EP, the following conditions
must be met: all 323003 in the
Example (B):
EP address, each riser has 25 floors,
and each floor has 8 handsets.
System configuration Mode 2 is used.
the Switchboard directly connected
to the main EP is no. 2 MC. Main EP
configuration should be as follows:
NOTE: there is an additional configuration slot “M”.
M= switchboard address number - can be set only by keyboard or by SF2 software.
poSition
Value for configurator
reMarkS
N
0
It is ok not to insert configurator 0
N
5
#F
2
#F
2
#I
0
It is ok not to insert configurator 0
#I
8
B
system should be numbered in
sequence. They must start from 1
and no number can be missed.
EP configuration examples
44