4.7 OPTIONAL DOOR TRIM KIT
The door trim kit includes a brushed stainless frame for each door,
and an air grill. To install the optional door trim, you'll first need to
remove the latch mechanism from the door. The process is the same
for each door.
1. Using a hex key wrench, loosen the set screw at the latch.
Remove the latch pin and latch handle.
2. Remove the door from stove. Lay the door face down on a
soft material.
3. Locate the four drill dimples on the inside corners of the
door. Using bit supplied (1/4”), drill a hole through each
corner. (two locations on ash door)
4. Insert the door trim studs through the holes. Using a nut
driver, secure with the supplied nuts. These nuts are placed
on the stud with the indented triangle side facing up. Before
tightening the nuts, check that the frame is properly nested
into the offset of the door. Do not over-tighten nuts. The
frame may distort or the stud can break loose from the frame
if over-tightened.
5. Place door back on the stove. Attach the latch by reversing
Step 1.
To install the air grill, remove the existing painted grill. Then, using
the same two screws and spring washers, install the brushed
stainless grill.
4.8 ROOM SENSOR INSTALLATION
Although not required, it is recommended that the room sensor be
connected in every installation. Using a minimum size 18 gauge
wire, you may splice in an additional length, to extend the room
sensor. The following are typical locations for the room sensor;
•
On an interior wall next to or in place of a typical wall
thermostat.
•
On the leg of a coffee table or end table in your favorite
sitting location.
•
Dangled behind the stove, hidden from view, acting as a
return air sensor.
Note: When installing the room sensor, limit the distance from the
stove to 25 feet or less.
Once the location has been decided, run the wiring to the rear of the stove. Crimp the two female terminals onto the ends of the wires
and plug them in to the port provided on the right rear portion of the stove. These connections are not polarity specific.
Note: If the room sensor is located too close to the appliance, or in a direct path of the distribution air, You may need to elevate the
temperature setting to maintain a comfortable temperature level throughout the heated space.
-25-
Содержание Super Magnum Coal Stoker
Страница 2: ......
Страница 4: ...Super Magnum Coal Stoker Label top not actual size 4 ...
Страница 5: ...Super Magnum Coal Stoker Label bottom not actual size 5 ...
Страница 6: ... 6 ...
Страница 12: ...2 4 COMPONENT LOCATIONS 12 ...
Страница 14: ...2 6 DIMENSIONS 14 ...
Страница 37: ...Reference Materials 37 ...
Страница 45: ...Service and Maintenance Log Date of Service Performed By Description of Service 45 ...
Страница 46: ...Service and Maintenance Log Date of Service Performed By Description of Service 46 ...