6.4.c Distribution Blower
Requires no lubrication – Change filter monthly to prevent build-up
of pet hair, etc. →
To remove distribution blower:
1. Remove filter retainer and filter.
2. Disconnect the three wires from the blower power cord.
3. Loosen 3 mounting screws which hold the motor into its
housing.
4. Lower the motor and squirrel cage fan out of the blower
housing.
6.4.d ESP – Exhaust Sensing Probe
Remove and wipe clean with a soft cloth and glass cleaner or
alcohol.
To remove the probe, you'll need to access the panel in the fuel
hopper.
(see below)
1. Remove the knob from the heat exchange scraper handle.
The knob is threaded onto the shaft.
2. Remove the access panel by loosening the screws.
3. With a 1/4" socket or driver, remove the screw that attaches the probe.
4. Pull the probe out of it's mounting hole.
6.4.e Fines Scraper – in Feeder
In the base of the hopper, there is a scraper plate that keeps the
coal fines flowing toward the fire. This scraper plate is designed to
be adjustable. To adjust, loosen the two bolts with a 7/16" wrench,
allow the scraper plate to rest downward against the top of the
pusher block, and re-tighten the two bolts.
→
-36-
Содержание Super Magnum Coal Stoker
Страница 2: ......
Страница 4: ...Super Magnum Coal Stoker Label top not actual size 4 ...
Страница 5: ...Super Magnum Coal Stoker Label bottom not actual size 5 ...
Страница 6: ... 6 ...
Страница 12: ...2 4 COMPONENT LOCATIONS 12 ...
Страница 14: ...2 6 DIMENSIONS 14 ...
Страница 37: ...Reference Materials 37 ...
Страница 45: ...Service and Maintenance Log Date of Service Performed By Description of Service 45 ...
Страница 46: ...Service and Maintenance Log Date of Service Performed By Description of Service 46 ...