15
4.7 Maintenance and repair
Caution!
The safety notes in section 4 apply!
The mechanical arrest system must not be repaired.
If damage occurs, the complete mechanical arrest system must be replaced!
The mechanical arrest system must be installed and removed by specialist personnel.
Maintenance must be performed under the best possible conditions.
In the event of an accident, a doctor must always be called.
The fixing bolts must be tightened correctly and with the correct torque (see section 8.4) and
secured against unintentional release.
For further information on maintenance, see the maintenance schedule in section 8 of these instruc-
tions.
Danger!
When cleaning parts with compressed air,
protective goggles must always be worn.
4.8 End-of-life, decommissioning, disposal
When the component is decommissioning, ensure that the environmental protection regulations
are observed. This means that different materials must be separated prior to disposal (different
metals isolated, plastic, rubber, electronics, etc.).
Mechanical parts must be separated from electrical, pneumatic and hydraulic parts, i.e. remove
cable harnesses, dismount motors, remove hoses, collect fluids etc.
All parts must be free of oil and grease. Oil and grease must be removed and disposed of in
accordance with regulations.
All parts that were lubricated during the product’s service life must be cleaned.
!
Regulations and legislation relating to the disposal of oil and grease must be complied
with. Companies that dispose of these materials must present the necessary authoriza-
tions.