background image

6

 

 

LEANTECHNIK AG

 

Im Lipperfeld 7c · D - 46047 Oberhausen

 

Telefon   ..49 (0) 208 · 495 25 - 0

 

Telefax  ..49 (0) 208 · 495 25 -18

 

E-Mail  

[email protected]

 

 www.leantechnik.com

Declaration of incorporation 

In accordance with the EU Machinery Directive 2006/42/EC, Annex II B: 

Name of manufacturer   

LEANTECHNIK AG 

Adress     

 

Im Lipperfeld 7c

   46047 

Oberhausen

   Germany 

We declare herewith that the partly completed machine designated below complies with the 

EU Machinery Directive 2004/42/EC and subsequent amendments through to its interfaces: 

Designation / type:  

   Mechanical arrest system (ASS) for

   lifgo

®

, lifgo

®

 linear, lean SL

®

 

 

 

sizes 5.0, 5.1 and 5.3 

 

Order number:                        Article:                        Date of manufacture:                     

 

The following harmonized standards apply: 

 

EN 12100       

Safety of Machinery, Basic Concepts Parts 1 and 2 

EN ISO 14121-1    

Safety of Machinery, Risk Assessment 

 

The designated partly complete machine is intended for installation in a machine or for assembly 

with other machines.

We declare that commissioning is prohibited until the machine or component in which this partly 

complete machine is installed or of which this partly complete machine forms a component 

complies in its entirety with the provisions of the Machinery Directive 2006/42/EC and the 

Declaration of Conformity as set out in Annex II A is available.

The present declaration shall cease to be valid in the event of any modification not agreed upon 

with us.

Authorised representative for the compilation of technical documentation:

Lukas Piofczyk (CE coordinator) 

 

Oberhausen, 

Date:  

                       

  Signature (Managing Director):  

                                     

 

Declaration of incorporation

Содержание lean SL

Страница 1: ...o lean SL 5 0 5 3 Mechanical arrest system Assembly instructions LEANTECHNIK AG Year of manufacture 2012 Datum 17 12 2012 Version 00 CE coordinator Lukas Piofczyk Editor Martin Siemann www leantechnik...

Страница 2: ...ns 10 3 3 Load capability 10 3 4 Adjusting drive 10 4 Safety instructions 4 1 General information on component operation 11 4 2 Choice of personnel and qualifications 13 4 3 Transporting the mechanica...

Страница 3: ...3 LEANTECHNIK AG 6 6 1 18 6 2 19 6 2 1 19 6 2 2 19 6 3 20 6 4 20 6 5 20 6 6 20 6 7 20 7 7 1 21 7 2 21 7 3 21 7 4 21 8 22 9 22 10 22 11 11 1 23 11 2 23...

Страница 4: ...mage to property or personal injury arising out of modifications or operations that do not conform to the present manual Copyright The reproduction of texts images or drawings either in whole or in pa...

Страница 5: ...omponent and the individual components it comprises The responsibility of the operator relates primarily to operating safety and maintenance of the component The manufacturer will accept no liability...

Страница 6: ...onized standards apply EN 12100 Safety of Machinery Basic Concepts Parts 1 and 2 EN ISO 14121 1 Safety of Machinery Risk Assessment The designated partly complete machine is intended for installation...

Страница 7: ...acceptance at LEANTECHNIK AG The scope of delivery does not include Electrical controller Operator controls Safety relevant connections overall concept Final installation Test run Commissioning Lubri...

Страница 8: ...the event of repair work The mechanical arrest system may only be used together with lifgo lifgo linear or lean SL All other uses and functions are prohibited Caution Divergent uses even if only in pa...

Страница 9: ...nical data data sheet A B D E F G M C2 H J1 K L J O H I J N C1 C3 M Schmierbohrung f r Lifgo und lean SL Ritzel Zahnstange Passbohrung F r Zahnstangeschut Steckanschluss f r Luftschlauch N herungsscha...

Страница 10: ...inion gear rack J mm M6 6 M10x1 10 M10x1 10 J1 mm 5 5 5 K mm 56 5 79 5 131 Dowel hole L mm 6F7 10 6F7 10 6F7 10 For gear rack protection M mm M4 M4 M4 Plug in connector for air hose N mm 6 6 6 Proximi...

Страница 11: ...including the elimination of problems troubleshooting In addition to the points mentioned throughout the manual the following points must be ob served when operating the component These safety instruc...

Страница 12: ...and signs on the component Take all possible preventive measures to avoid injury or damage of any type Make sure that the component can be operated and repaired safely under all circumstances Potentia...

Страница 13: ...ed personnel with specialist training mechanics electrical engineering Transport X Installation X Commissioning X Setup X X Normal operation X X Cleaning X X Maintenance X X Troubleshooting and correc...

Страница 14: ...parts have been supplied and are available All the parts must be installed correctly The electrical and pneumatic connections must be established We cannot accept liability for errors or damage of an...

Страница 15: ...sed air protective goggles must always be worn 4 8 End of life decommissioning disposal When the component is decommissioning ensure that the environmental protection regulations are observed This mea...

Страница 16: ...f applicable international safety regulations must be observed during maintenance cleaning repair installation and troubleshooting operations The safety instructions and provisions set out in the main...

Страница 17: ...t may then be unable to perform its function When lifting and putting down the component avoid any jolts or impacts Any load lifting equipment such as eye bolts straps or cables must be designed to su...

Страница 18: ...cylinder and the spring pressure forces the toothed bar to wards the gear rack The inductive switch at the air cylinder indicates that the mechanism has left its free moving position The system is no...

Страница 19: ...6 2 Installation positions 6 2 1 Gearbox moves the lift load 6 2 2 Gear rack moves the lift load 6 Function description 19...

Страница 20: ...t be moved to the required height The locking mechanism is then activated by depressurizing the mechanical arrest system s lifting cylinder Complete locking is only ensured once the system has slowly...

Страница 21: ...est system is lubricated for life 7 4 Lubrication and maintenance points To ensure the long term maintenance free operation of the component and reduce technical prob lems to a minimum it is necessary...

Страница 22: ...ndard parts LEANTECHNIK AG s suppliers are listed below Name Supplier Electrical components Festo Pneumatic components Festo 10 List of documents and drawings Further individual documents and drawings...

Страница 23: ...any doubt it is essential to contact the component manufacturer 11 2 Table Fault Possible cause Solution Mechanical arrest system does not lock Release bar not engaged in tooth space Repeat procedure...