Operating Instructions
– LBA63 TOLL HIGHWAYS – 2019 Version
55
None
Red light:
The barrier is not open or is about to close.
Passage is prohibited.
The "Red light" output is activated.
None
Green light:
The barrier is open and is not about to close.
Passage is authorised.
The "Green light" output is activated.
Safety detection
The barrier is open and detects a presence on
the safety loop and/or in front of the infrared
(or ultrasound) cells.
Closing is impossible.
Unhinged
barrier
–
Unhinged
The barrier is unhinged or the arm has fallen.
Barrier in fault
– Fault
The barrier is in fault. Motor control is cut off.
List of possible faults:
-
The time delay for manoeuvring
was exceeded (obstacle, broken
reduction
gear,
defective
sensors…)
.
-
The crank is not in place
-
The motor is not (or is incorrectly)
connected
-
A
phase
of
the
motor
is
disconnected
-
A phase of the motor is short-
circuited
-
The connected motor is not the
correct motor
If the web server's home page is not sufficient to correctly view the barrier or if you want to configure
the barrier, there are other tabs for a more in-depth use of the web server.