Operating Instructions
– LBA63 TOLL HIGHWAYS – 2019 Version
45
(TRUE: activated; FALSE: deactivated).
PWM_verrou
Activation of the PWM function on the
locking output (Q3) in order to consume
less
(TRUE: activated; FALSE: deactivated).
●
●
English
Activation of English messages on the
screen
(TRUE : English ; FALSE : French).
●
●
Param_Vit_1
Opening speed of the barrier.
Hz
●
●
Param_Vit_2
Closing speed of the barrier.
Hz
●
●
Param_Vit_3
Slowdown speed (holding torque) in
opening
Hz
●
●
Param_Vit_4
Slowdown speed (holding torque) in closing
Hz
●
●
Param_Vit_5
Acceleration ramp of the barrier in opening.
Hz/s
●
●
Param_Vit_6
Acceleration ramp of the barrier in closing.
Hz/s
●
●
Param_Vit_7
Deceleration ramp of the barrier in opening.
Hz/s
●
●
Param_Vit_8
Deceleration ramp of the barrier in closing.
Hz/s
●
●
Param_Vit_9
Opening speed of the barrier during
automatic rehinging.
Hz
●
●
Regondage_auto
Activation of the automatic rehinging
function (LBA63PG)
(TRUE: activated; FALSE: deactivated).
●
Reversibilite
Option to be activated when the barrier is
reversible in order to activate the "holding
torque" function
(TRUE: activated; FALSE: deactivated)
●
Reouverture_secu
Activation of the automatic reopening on
detection of a safety component (loops, IR
cell, ultrasound, etc.)
(TRUE: activated; FALSE: deactivated)
●
Param_Boost_1
Value of the boost applied to the motor
during movement
%
●
Param_Boost_2
Speed below which a boost is applied to the
motor in movement
Hz
●
Param_Boost_3
Value of the boost applied to the motor
during holding torque
%
●
Param_Boost_4
Speed below which a boost is applied to the
motor in holding torque
Hz
●
Param_Motor_1
Maximum value of the current that can be
applied to the motor during movement
A
●
Param_Motor_2
Maximum value of the current that can be
applied to the motor during holding torque
A
●
Param_Motor_3
Choice of the motor to control:
1: Motor 0.18kW 1.2A Bonfiglioli
2: Motor 0.25kW 1.5A Leroy Somer
3: Motor 0.55kW 3A Bonfiglioli
4: Motor 0.25kW 1.4A Bonfiglioli
●
Sens_barriere
Direction of rotation of the motor
(1; -1)
●