Maintenance and service
Channel module 950/41:
40/ 58
V 1.2
zirkon User Manual
CAN SPEED
The left LCD button shows the current speed of the CAN
bus interface.
1.
Turn the rotary control to adjust the speed! (500k,
100k, 10k)
All components of a CAN bus must be set to the same
rate or no communication is possible.
2.
Push the “SAVE” button to adopt the selected
settings!
3.
Push the “QUIT” button to reach the main menu!
FADER KAL
The automated calibrating of faders is only necessary
after replacing a fader. After an operating time of about
two years a fader calibration is recommended. Apart from
that it is not necessary. This way you start the calibrating
procedure.
1.
Press the button “START KAL”!
The calibrating starts. The calibrating is finished when the
display of the “START KAL” button changes to “FADER
READY”.
2.
Push the button „SAVE” to adopt the new measured
results!
3.
Push the button “QUIT” to reach the main menu!
UNLOCK
SAVE
QUI T
500k
Note
START
KAL
QUI T
SAVE
UNLOCK
Tip