Introduction: the zirkon system
Components of the zirkon system
12/ 58
V 1.2
zirkon User Manual
•
Motor faders are standard
The motor faders allow the transparent operation in
combination with a radio automation system
(connection of automation via serial protocol,
RS422).
•
CAN bus connection
Control panel and system unit are connected via CAN
bus. 19’’ 1RU button panels (KS16) can be also
integrated.
•
Simple installation
The system is cabled via RJ45 plug-in connectors.
•
56/64-channel MADI interface
The system can be extended by this interface. The
interface is designed redundantly.
Components of the zirkon system
Fundamentally, a system consists of one System Unit and
at least two control panel modules (Central Module and
Channel Module).
The
system unit
includes the masterboard and a number
of analogue and/or digital interfaces. The motherboard
performs the signal processing. The interfaces serve for
integrating the studio environment.
With the
central module
you operate monitoring
functions, many programmable special functions and the
signal processing of individual input signals. The
channel
module
includes four channel strips. Each channel strip
is fitted with one motor fader and five buttons. You can
connect up to nine channel modules to the system.