Maintenance and service
System page (http:// )
38/ 58
V 1.2
zirkon User Manual
DSP card information
Local Date
and
Local Time
show the system time and the
date. The addition NTP indicates that a connection with a
NTP server is established.
Every master board works with three voltages. The current
value can be found out under the entries Voltage 1, 2, and
3. Nominally,
Voltage 1
is 1.8 V,
Voltage 2
is 3,3 V and
Voltage 3
is 12 V.
Temperature
displays the temperature of the master
board in Celsius.
The temperature of 947/81 should not exceed 45° C.
This indicator does not give information about the
temperature in the rest of the frame or in the rack.
It can be only used to find out a tendency.
Sync Information
SyncCard: Madi: Wordclock: Intern: present enable active
Slot Information
This table represents the plug-in cards of the DALLIS
frame. Under “slot” you find the number of the slot. Card
ID signifies the module number. Card type gives a short
term of the card type.
Panel Information
Supplementary Information
This part shows general statistic system information.
Deskname
displays the console name that is entered in
the configuration.
Last Restart
shows date and time.