mc²96 Installation & Service Guide
Version: 1.0/3
51/65
5. Service Procedures
5.9.1
Adjusting the Bayserver Settings
The instructions below apply to a channel Bayserver. However, the settings for a Gateserver can be adjusted in
a similar manner.
The Bayserver (or Gateserver) is mounted behind the bay's TFT display. Therefore, you will need to remove the
display to access its switches.
DO NOT
attempt to open the frame without first disconnecting the mains supply.
1.
Remove the TFT display from the bay you wish to adjust as described
2.
Locate the S1 DIP switches and SW1 rotary switch on the Bayserver circuit board. The location and
function of all connectors and switches is explained on the sticker.
3.
Set the
S1
DIP switches to the desired ON/OFF positions. Take care to set the correct positions, as the
switches are mounted upside down when viewed from the front buffer.
4.
Set the
SW1
rotary switch to the required address.
5.
Replace the TFT display.