36
Large Amount of Water Remains in Capsule After Dispense
Issue:
After dispensing a beverage, a large amount of water remains in the capsule.
Solution:
Two possible conditions will create this situation:
1.
The mix stream is improperly calibrated. The mix stream will run
beyond the proper time and continue to fill the capsule. This is
usually accompanied by a dispersed dispense stream spraying all
over. Recalibrate the mix stream to eliminate this condition.
2.
The capsule is not raised fully to 90 degrees vertical. This is
usually caused by an unclean chamber that prevents the
capsule drive mechanism to stop short of 90 degrees. Clean the
chamber fully. Remove the capsule tray. Pull the linkage attached
to the lid towards you. Reach down underneath the linkage and
grasp the drive mechanism (solid black plastic piece with a semi-
circle opening). Pull the drive mechanism all the way towards you
until it reaches 90 degrees. Push it all the way back until it stops.
Do this a couple of times. Replace the capsule tray and dispense
a beverage.
A Dirty capsule tray may
stick !
Correct position