19
18-11-26-REV-A
No Still Water Dispense
Issue:
The unit will not dispense cold still water nor create a still water beverage. Soda water
dispense is normal.
Solution:
This condition is due to a faulty still water pump or still water pump connection. Remove
the top of the unit keeping the connectors attached. Observe the main PCB and the 4th
connector from the left on the top row of connectors (a red connector with dual leads
- two white and a red and black). Press and hold the Lavit button. A red light should
illuminate on the main PCB next to the connector indicating power to the dispense
pump. If the light does not illuminate then replace the main PCB. If the light does
illuminate ensure that the red connector is properly seated on the main PCB. Follow
the red and black leads back towards the dispense pump and locate the secondary
connection. Ensure that connection is properly seated. If the pump does not power on
after checking the PCB and connections replace the dispense pump.
Still Water pump