27
18-11-26-REV-A
8.
Tilt the brewer assembly on its side to gain access to the 2-soda
solenoid mounting screws. Remove the screws and the soda solenoid.
9.
Turn the soda solenoid upside down and remove the 2 small screws that
hold the white plastic base to the magnetic drive. Note the orientation of
the red and blue water ports to the magnetic drive. This will help you in
reassembling the solenoid.
10.
Carefully remove the white plastic base and locate any foreign material in
the flow chamber or on the red rubber seal at the end of the plunger. Be
careful in handling so that the O-ring, plunger spring, and 2 small screws are
not misplaced.
11.
When the foreign material has been removed reassemble the solenoid in
its original orientation.
12.
Remount the solenoid to the brewer assembly.
13.
Remount the brewer assembly to the unit. It is recommended you start at
the right rear screw and properly place the spacer washers and then start
the mounting screw. Secure the base.
14.
Reinsert the inlet and outlet tubing. Reconnect the soda solenoid (black
male and female connection).
15.
Power unit on. Turn the CO2 pressure on to 3.5bar.
16.
Verify that all dripping has stopped.
17.
If this has resolved the issue -reinstall left side panel and the top panel.
18.
If this did not resolve the issue replace the soda solenoid valve. See valve
location below.