Water Chilling Screen
Issue:
When water is dispensed or a beverage is created a new dispense cycle cannot be
performed because the Water Chilling Screen is on.
Solution:
The MAX TEMP function in the service menu has been enabled. Enter the service
menu and select MAX TEMP. IF THE DISABLE icon is present. Press the DISABLE icon
and the ENABLE icon will appear.
Other Comments:
The units come factory set with this feature disabled. A service technician or a
customer who has the password has gained access to the service menu and enabled
the feature. This feature DOES NOT set the water temperature of the unit. It sets
the maximum temperature allowed for water or beverage dispensing. This feature is
set at the factory 41 degrees F.
The incorrect icon
displayed is “Disable”
The
correct
icon displayed is
“Enable”