“Close Brewer Lid” Error when Brewer Closed
Issue:
The touchscreen displays a "Close Brewer" message but the brewer lid is in
the closed position.
Solution:
The close brewer message will be displayed when the brewer lid is closed
under three circumstances:
1.
Ensure that the brewer magnet is present. Open the brewer and locate the
magnet on the right hand outside wall on the brewer lid. It will be a small
1/4" metallic disc pressed into the external side wall. If the magnet is not
present insert a replacement.
2.
The ribbon connector is loose on the main PCB. Remove the top panel
cover. Pull back the plastic cover over the main PCB located on the front
right of the unit. Verify that the black ribbon connector on the far left of
the PCB is firmly attached and the two locks are in place. Disconnect and
reconnect as necessary.
3.
If neither of the above clear the error check the Hall Sensor connection to
the ribbon cable. With the top panel removed locate the magnet and Hall
Sensor attached to the external wall of the brewer 1
st
ensure the magnet
is in place. If not replace it. Then make sure the sensor lead is properly
connected to the main ribbon cable. If it is and the error remains then
replace the Hall Sensor
Magnet- this activates
the Hall sensor when lid
is closed
Hall Sensor. This let
the board know if
the lid is open or
closed