“Possible
Water
Leak”
Error Screen
Issue:
During start up or during normal operation the unit will display "A Possible Water
Leak" error message screen.
Solution:
This error message appears when the inlet solenoid to the unit has been open
for more than five minutes. Under normal circumstances tank filling or refilling
should not take more than five minutes. If there was a major water leak inside
the unit then the unit would shut down until a repair is made. A false error
message will occur under the following circumstances:
1.
A plumbed in unit with low inlet water pressure. If the water pressure
going into the unit is less than 30 psi then the 5-minute cycle could time
out and the error message will appear. Turn unit off and restart to clear the
error. Dispense a cup of water to reopen the inlet solenoid. This may
happen frequently during a new install since the amount of water
necessary to fill the tanks may exceed the inlet water line's capacity of 5
minutes. Restart and clear error. Dispense water to o p e n solenoids.
2.
A bottled water unit with a Flo-Jet or Lavit pump will show this error if the
bottle is empty or the pump is not on. Check to make sure your water
bottle has adequate water remaining in it and that the pump is powered on.
Replace bottle water if needed. Turn off the unit and restart. Dispense two
cups of water making sure the pump is on. This will clear any air blocks in
the line and the tanks should refill as normal.
3.
The water tanks are not filling due to a solenoid or float issue. See Water
Tanks
Not Filling at Start Up Page 24-25 in this manual.
9
18-11-26-REV-A