25
sys admin>>MODEM
Enter accepts present value
Init string | > ATB2H0
Save changes and update modem card? Yes or No: No>yes
Modem card not installed in slot A, init string saved
Sys admin>MODEM /DEFAULT
Current modem init string is: ATB2H0
Set modem to factory default value of: ATH0S0=1
(write out YES) Yes or No: No>yes
Modem card not installed in slot A, init string saved
sys admin>>
The administrator may also reset the initialization string to the default value by
entering the command with the default qualifier in the form
MODEM /DEFAULT
.
When using the
/DEFAULT
qualifier, the current initialization string is displayed,
along with the factory default string. The administrator is asked to confirm the
use of the default modem string; typing
YES
and
<ENTER>
will send the default
initialization string immediately to the modem card, while typing
NO
and
<ENTER>
keeps the old modem string.
It is recommended that the default modem initialization string be used unless the
application requires that it be changed. The default initialization string is
ATH0S0=1
, which disconnects any active phone connections when the
initialization string is sent, and sets the modem to auto-answer on one ring.
4.6 Status
Commands
There are four commands which allow the administrator to check the status of
the ConsoleServer 800:
CONNECTIONS
,
VERSION
,
INFO
, and
POWERSTATUS
.
4.6.1
CONNECTIONS
CONNECTIONS
CONNECTIONS
CONNECTIONS
Command
The administrator may monitor the status of connections made through the
terminal, network port, and modem port by using the
CONNECTIONS
command.
This command will display all the active connections and the mode of those
connections as follows: