English

SE700 / SE500 / SE300  

Basic Operating Manual 
 

FUJITSU Server BS2000

 

 

Summary of Contents for SE300

Page 1: ...Edition June 2015 English SE700 SE500 SE300 Basic Operating Manual FUJITSU Server BS2000 ...

Page 2: ...e free bleach Copyright 2015 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The Xen mark is a trademark of Citrix Systems Inc which manages the mark on behalf of the Xen open source community The Xen mark is registered with the U S ...

Page 3: ...acturer 15 2 1 1 For safe operation 15 2 1 2 About this product 15 2 1 3 Trademark acknowledgments 16 2 2 Note regarding radio interference suppression 16 2 3 Note on safety 17 2 3 1 Important alert messages 17 2 3 2 Maintenance 18 2 4 Installation and operation precautions 18 2 4 1 Installation precautions 19 2 4 2 Operating precautions 20 3 System overview 21 3 1 Features 21 3 1 1 Rack of the SE...

Page 4: ...es 45 5 3 2 1 UNIT EMERGENCY switch 45 5 3 2 2 POWER ON key 45 5 3 2 3 STAND BY key 46 6 Management Unit 47 6 1 Front of the MU 49 6 1 1 Controls 50 6 2 Rear of the MU 53 7 Net Unit 57 7 1 Switches 58 7 1 1 Front 58 7 1 2 Network and management interfaces 59 7 1 3 LED indicators for ports system and power status 60 7 1 4 Threshold values for the operating temperature 63 7 2 Extension of the Net Un...

Page 5: ...mergency 66 8 1 2 Switching the SE server on 67 8 1 3 Switching the SE server off 69 8 2 Switching the SE700 SE500 on and off 71 8 2 1 Switching off in an emergency 71 8 2 2 Switching the SE server on 73 8 2 3 Switching the SE server off 76 9 Environmental protection and service 79 Abbreviations 81 Related publications 83 Index 85 ...

Page 6: ...Contents U41858 J Z126 1 76 ...

Page 7: ...inux Windows VMware OVM etc Shareable tape and disk periphery A high speed server internal infrastructure to connect the components with each other and with the customer s IP or FC network The SE server is installed entirely and tested on the vendor s premises in accordance with customer specifications Many hardware components are redundant in design thus ensuring that even if a fault occurs with ...

Page 8: ...Introduction 8 U41858 J Z126 1 76 Figure 1 SE server SU700 ...

Page 9: ...dme files for the various product versions These Readme files are available at http manuals ts fujitsu com under the various products Current information version and hardware dependencies and instructions for installing and using a product version are contained in the associated Release Notice Release Notices in particular those relating to BS2000 OSD XC M2000 X2000 and HNC are available at http m...

Page 10: ...ople who operate an SE server As administrator you manage the entire SE server with all its components and the operating systems which run on it You need a good knowledge of the BS2000 Linux and Windows operating systems and of the network and peripherals As administrator you can also manage the integration of the optional Application Units on which an open operating system runs in Native or virtu...

Page 11: ...anual Information on the modules of the operating manual can be found in section Documen tation for the SE servers on page 9 The Glossary explains important terms used in this manual The Abbreviations chapter gives an overview of the abbreviations that have been employed in this manual References to publications are given in the text with shortened forms of the titles in quotes The Related publica...

Page 12: ...This indicates information that could help the user to use the product more effectively Ê The prompt symbol indicates activities which need to be performed e g entries on the keyboard italics Texts from the SE Manager monospace System inputs and outputs monospace semibold Statements which are entered via the keyboard are displayed in this font abc Variables which are replaced by values Key symbols...

Page 13: ...rver Unit with one or more x86 processors A distinction is made between the following SUs according to models SU300 for the Server Unit of the unit type SU x86 in SE300 optionally in SE500 SE700 SU500 for the Server Unit of the unit type SU 390 in SE500 SU700 for the Server Unit of the unit type SU 390 in SE700 MU for the Management Unit The MU permits central user friendly and cross system manage...

Page 14: ...eries 390 architecture SQ server for the business servers of the SQ series x86 architecture BS2000 for the BS2000 OSD BC operating system in compound nouns e g BS2000 system 1 5 Open Source Software The Linux based operating systems X2000 and HNC which are installed on the Server Unit x86 Management Unit and HNC contain Open Source Software The licenses for this can be found in the LICENSES direct...

Page 15: ...further reference The manufacturer makes every effort to prevent users and bystanders from being injured or from suffering damage to their property Use the product according to this manual 2 1 2 About this product The FUJITSU Server BS2000 of the SE Series is designed and manufactured for use in standard applications such as computing center work office work and general industrial applications Thi...

Page 16: ... States and in certain other countries All other product names mentioned herein are the trademarks or registered trademarks of their respective owners System and product names in this manual are not always noted with trademark or registered trademark symbols The contents of this manual may be revised without prior notice Copyright 2015 Fujitsu Technology Solutions GmbH All rights reserved Delivery...

Page 17: ...ution units which are integrated into the rack Attach the connection cables of the multiple socket outlets to the in house installation so that they are easy to access Do not connect any additional consumer loads to the power distribution units this could cause the nominal load capacity of the multiple socket outlet or feed cables fuses to be exceeded If you want to connect additional equipment pl...

Page 18: ...nting de mounting of optional internal devices Plugging or unplugging of external interface cables Maintenance and inspections repairing and regular diagnostics and mainte nance v CAUTION All maintenance measures for this product and the optional products of the manufacturer may only be performed by Customer Support Users must not perform these tasks Incorrect operation of these tasks may cause ma...

Page 19: ...ount of air flow is required for safe operation of the server components The server components have ventilation openings at the front and rear Do not cover or close the ventilation openings Doing so may cause the server components to overheat Positioning the Business Server may cause the entire rack to be unstable because of uneven mechanical loading The racks of the SE server have no stabilizer W...

Page 20: ...le beneath any equipment Also prevent cables from becoming taut Never disconnect the power cable of the Server Unit while power is being supplied to the SE server Keep objects off the rack and the rack components Never use the rack as a work area Do not allow condensation to form In winter slowly raise the ambient room temperature to prevent condensation from forming in the Server Unit Use the SE ...

Page 21: ...s SVP operation Remote service of the SE server is performed by means of AIS Connect over the internet For AIS Connect the Management Unit requires an internet access over the administration LAN The customer operates the access for remote service via the SE Manager Server Unit A 390 based Server Unit SU 390 enables operation of BS2000 Native BS2000 or VM2000 An x86 based Server Unit SU x86 enables...

Page 22: ...sed AU permits operation under Linux Windows or VMware Peripherals storage Optional hardware components Up to two ETERNUS JX40 disk storage systems can optionally be integrated into the rack to back up the user data and connected to an SU x86 or AU Further disk storage systems e g ETERNUS DX can optionally be connected via Fibre Channel ETERNUS LT40 S2 tape libraries with LTO drives can optionally...

Page 23: ...the SE300 is equipped with the components of the basic configuration and with optional components Figure 2 System components SE300 SE300 Basic configuration SE300 with optional components SU300 SU1 SU300 SU2 AU47 AU1 AU47 AU2 MU MU1 MU MU2 DX500 S3 DS DX500 S3 DS DX500 S3 contr Service drawer Rack console Net Unit 1 Net Unit 2 ...

Page 24: ...the basic configuration and with optional components The equipment is comparable for the SE500 Figure 3 System components SE700 SE700 Basic configuration SE700 with optional components CHE box 0 CHE box 1 HNC 2 MU MU1 SU700 Service drawer Rack console Net Unit 1 Net Unit 2 CHE box 4 HNC 1 CHE box 5 CHE box 2 CHE box 6 CHE box 3 CHE box 7 FUJI C9 CPU box ...

Page 25: ...ver Unit s and Application Unit s Detected faults are displayed in the SE Manager and reported to the vendor s Support Center via remote service v CAUTION You are forbidden from repairing components of the server yourself Maintenance and repair of the server components are performed solely by Customer Support If a fault occurs please always contact Customer Support Detailed information on the moni...

Page 26: ...Features System overview 26 U41858 J Z126 1 76 ...

Page 27: ... a 19 inch standard rack In the case of the SE700 and SE500 the control panel is located on the front see section Control panel on the SE700 and SE500 on page 42 If the basic rack is not longer adequate for larger configurations extension racks can be used Figure 4 Basic rack of the SE server SE700 SE 500 SE300 ...

Page 28: ...Extension rack The extension rack is a 19 inch standard rack which accommodates additional components for which there is no more space in the basic rack Figure 5 SE server with an extension rack e g SE700 In all an SE server can comprise four racks ...

Page 29: ...ower grid with CEE connectors 32A blue For redundancy reasons two phases are required Two of the four CEE connectors are connected to each phase SE300 The power distribution units to be installed in the SE300 basic rack and in the extension racks can be selected The following three types of PDU can be installed PDU with 10 x C13 outlets CEE connector 16A blue 3 phase PDU with 3 x 8 x C13 outlets C...

Page 30: ...l work on the power supply must be conducted by Customer Support Connect each power cable to a grounded service outlet located within the operator s reach The power cables must be connected in such a manner that the power consumption of the rack components does not exceed the maximum rated current of the circuit s fuse and the maximum permissible current of the fuses in the power distribution unit...

Page 31: ...nsole switch on page 41 After you have logged in on the local console you can call the SE Manager via the local desktop s browser Safety instructions Pull the rack console slowly toward you until the slide rails lock If the slide rails are not locked the rack console can move unexpectedly Be careful not to catch your fingers when you pull or push on the slide module or when you open or close the L...

Page 32: ...sole out of the rack Ê Loosen the finger screws 1 Ê Pull the rack console while you hold the handle 2 until it locks into place Opening the rack console Ê Use the handle to push the cover of the Rack Console up until the monitor is open at an angle of 110 degrees 0 ...

Page 33: ... this button to open the menu to select an item to be adjusted and to save an adjusted setting 4 UP button Press this button to select the right hand item or to increase the value 5 DOWN button Press this button to select the left hand item or to increase the value 6 AUTO EXIT button Press this button to close the menu to cancel the selection of an item to be adjusted to cancel an adjusted setting...

Page 34: ...nitor on Notes on the LCD Display While the on screen display may shift blink or otherwise be disturbed just after the power is turned on or the OS starts up shuts down this does not indicate a machine failure and the device may be used normally While 1280 1024 is the native full screen resolution the LCD display is full screen for all resolutions For resolutions other than 1280 1024 characters ma...

Page 35: ...indicated by the characters for example Scr Lk Prt Sc and SysRq When the Num Lock LED is lit the functions indicated by the enclosed characters shown on some keys are enabled HOT KEY and RESET key The following indicators and buttons are located on the right above the keyboard HOT KEY Pressing the HOT KEY outputs the code of the CTRL key twice causes the menu of the connected console switch to be ...

Page 36: ... touchpad surface twice or click the left button twice Dragging Lightly tap the touchpad surface twice and without releasing your finger from the touchpad surface slide your finger to move the cursor to the desired position and then release your finger from the surface Or while holding down the left button slide your finger to move the cursor to the desired position and then release your finger fr...

Page 37: ...or pencil Operating the pointing device with two or more fingers Operating the pointing device while something is on the touchpad Operating the pointing device while water drops are on the touchpad surface while condensation is formed on the touchpad surface or with a wet finger If the touchpad surface or your finger is wet dry or wipe water well before you use the touchpad Do not use a pointed me...

Page 38: ...on see Power button on page 33 to turn off the monitor Closing the monitor Ê Make sure that the front USB connector 1 is empty before closing the monitor It is not envisaged for use with the SE server Ê Use the handle 2 to push the cover of the Rack Console carefully down until it clicks into place 0 ...

Page 39: ...58 J Z126 1 76 39 Sliding the rack console into the rack Ê Press the buttons 1 to release the rack console Ê Use the handle to slide the rack console ino the rack until it clicks into place 2 Ê Tighten the finger screws 3 0 1 1 ...

Page 40: ...rectly connected to the server Notify Customer Support The screen flickers The monitor is incorrectly connected to the server Notify Customer Support Symptom Cause Action Grid screen that flickers The monitor is unfocused Adjust the focus of the monitor Vertical stripes are visible Monitor adjustment is not correct Adjust the clock and then adjust the display position Sometimes no images are displ...

Page 41: ...y default the rack console is attached to the Management Unit The console switch is a 16 port KVM switch In the maximum configuration 5 KVM ports 2 x MU and 3 x SU x86 are occupied in the SE300 and 8 KVM ports 2 x MU 4 x HNC and 2 x SU x86 in the SE500 SE700 For the SE300 at least 11 free ports thus remain available to connect AUs and for the SE500 SE700 at least eight free ports If more AUs are t...

Page 42: ...rol panel is located on the outside The control panel is connected to the service processor SVP of the SU700 SU500 of the SE server Further information on the SU700 and SU500 is provided in the Server Unit 390 Operating Manual 2 The physical layout of the control panel is shown in the figure below Figure 7 Operating panel on the rack of the SE700 and SE500 1 3 2 4 5 6 ...

Page 43: ... lamp Switches the Server Unit on When the SU 390 is switched on POWER ON lights up green 3 STAND BY button Switches the SU 390 off but not currentless power supply units in standby mode 4 SYSTEM lamp Displays whether the CPUs of the SU 390 are active 5 CHECK lamp Shows whether a fault has occurred 6 STATUS indicator Supplies detailed information on the hardware status The function of the displays...

Page 44: ... code for a problem In this case Customer Support should be contacted POWER ON STATUS indicator Hardware status Does not light up Does not light up Power failure Does not light up b00 through bFF Power supply units are being initialized Flashing Does not light up in maintenance mode CE0 Standby mode Lights up 001 through 010 Power on sequence is active Lights up 100 through 399 System is being ini...

Page 45: ...ts are switched off Switch off the fuses in the power distri bution cabinet to eliminate this danger Procedure in the event of an emergency power off 1 Pull out and remove the protective cover of the UNIT EMERGENCY switch 2 Move the switch down from position I to position 0 5 3 2 2 POWER ON key This key initiates the sequential power on of the power supplies of the entire 390 system 390 CPU AROMA ...

Page 46: ...the power supply of the entire 390 system It is switched off independently of an automatic power on off function v CAUTION There is a risk of data loss When standby mode is switched to using the key or the SVP frame it is not guaranteed that system data can be written back Terminate applications which are running beforehand and shut down the operating system w IMPORTANT In standby mode some of the...

Page 47: ...nits and fans are redundant in design The internal disks power supply units and fans can be replaced during ongoing operation The rack console serves as a monitor for the Management Unit and consequently as a local access administrative and operating functions of the SE server The M2000 software is preinstalled ex works Detailed information on operating the Management Unit is provided in the Opera...

Page 48: ... Figure 8 Management Unit MU front Figure 9 Management Unit MU rear figure 9 shows the MU of an SE300 with PCIe slots which are not equipped In the SE500 and SE700 one or two PCIe slots of the MU are equipped see also figure 15 on page 56 ...

Page 49: ...r MAC addresses and DNS name 1 HDD fault indicator 10 HDD activity indicator 2 Power supply fault indicator 11 Status indicator 3 Temperature fault indicator 12 On Off button 4 CPU fault indicator notify Customer Support 13 NMI button for Customer Support only 5 Storage fault indicator notify Customer Support 14 Reset button for Customer Support only 6 Fan fault indicator notify Customer Support 1...

Page 50: ...y pressing the On Off button once When the MU in is in operation it is switched off by pressing the On Off button once V CAUTION Possible loss of data I The On Off switch does not disconnect the server from the voltage grid To disconnect from the mains completely remove the power plugs RST Reset button Pressing the Reset button reboots the MU V CAUTION Possible loss of data NMI NMI button V CAUTIO...

Page 51: ...n when the MU has been switched on and is in standby mode or in sleep mode Hard disk activity indicator green Flashes green when an internal hard disk drive is being accessed CSS CSS and Global error indicators yellow orange Generally the states of these indicators have the following meanings Do not light up when the MU is OK If the event is still acute after a power failure the indicator is activ...

Page 52: ...nge in conjunction with a RAID controller Does not light up no HDD error Lights up HDD Faulty or Rebuild Stopped drive defective needs replacing a rebuild process was stopped or the HDD module is not correctly inserted Slow flashing HDD Rebuild the data is being restored after changing a hard disk drive Fast flashing HDD Identify Four fast flashes pause HDD Predicted Fault Two fast flashes pause H...

Page 53: ...e status can be reported to the ServerView Operations Manager and the iRMCS4 CSS CSS and Global error indicator yellow orange Generally the states of these indicators have the following meanings Do not light up when the MU is OK If the event is still acute after a power failure the indicator is activated after the restart Light up when a prefailure event was detected The indicator also lights up i...

Page 54: ...AN transfer rate of 1 Gbps Lights up green for a LAN transfer rate of 100 Mbps Does not light up for a LAN transfer rate of 10 Mbps 2 LAN connection transfer Lights up green if a LAN connection exists Does not light up if no LAN connection exists Flashes green when a LAN transfer is in progress System LAN ports SYS1 SYS2 unused ...

Page 55: ...h is very high The fan speed is very low In each of these cases please notify Customer Support 1 Indicator on hot plug power supply unit two colors Flashes green when the MU is switched off but line voltage is present standby mode Lights up green when the MU is switched on and functioning properly Flashes orange when a predictable error has been detected but the power supply unit is still running ...

Page 56: ...the various model series of the SE server The MU can be equipped with a second FibreChannel card in the free PCIe slot S1 This means that two more ports are available for the ROBAR connection and cluster function ality PCIe slot SE700 SE500 SE300 S1 Not assigned Not assigned Not assigned S2 USB card USB card Not assigned S3 FibreChannel card FibreChannel card Not assigned Table 2 PCIe slot assignm...

Page 57: ...he Net Unit contains the following components Switches A redundant Net Unit has redundant switches by default in the case of SE700 and SE500 Optional port extension A redundant Net Unit can be complemented by a redundant port extension to increase the number of redundant LAN ports HNC in the SE700 and SE500 The HNC connects the Server Unit 390 with the LAN Up to 4 HNCs are possible Future extensio...

Page 58: ...50 24 with 24 copper ports 10 100 1000 Mbps 4 optical ports SFP 1 oder 10 Gbps uplink ports stacking capable ICX 6450 48 with 48 copper ports 10 100 1000 Mbps 4 optical ports SFP 1 oder 10 Gbps uplink ports stacking capable i Currently maximum transfer speeds of up to 1 Gbps are supported Future exten sions of the Net Unit will support up to 10 Gbps 7 1 1 Front Figure 16 Net Unit ICX 6450 24 front...

Page 59: ...agement interface RJ45 port by default not used On 24 port models the management interfaces are arranged at the center on the front and on 48 port models on the left hand side at the front see the figures below Figure 18 Network and management interfaces ICX 6450 24 Figure 19 Network and management interfaces ICX 6450 48 Explanation 1 Console management port 2 Slot 2 SFP and SFP uplink or stacking...

Page 60: ...status On Brocade ICX 6450 models LEDs indicate the status of the ports of the system and the power status of the device Port status LED indicator Figure 20 Port status LED indicator ICX 6450 24 Figure 21 Port status LED indicator ICX 6450 48 1 or 1 and 2 display the ports with status LEDs ...

Page 61: ...e port exists SFP SFP X1 X4 Lights up green when the port is transferring 10 Gbps Lights up green and flashes when data packets are being transferred and received Lights up yellow when the port is transferring 1 Gbps Lights up yellow and flashes when data packets are being transferred and received Does not light up when no connection to a remote port exists Out of band management port 2 LEDs Not u...

Page 62: ...us LEDs is only relevant for the service technician Information on the status of the Net Unit which is relevant for the customer is displayed by the SE Manager in the main menu Hardware IP networks Power status LED indicator Figure 23 Power status LED indicator IXC 6450 24 Figure 24 Power status LED indicator IXC 6450 48 1 shows the power status LED ...

Page 63: ...perature exceeds the high limit temperature threshold TB the fan operates at maximum speed When a lower threshold value is fallen below the fan speed is reduced LED Display and meaning PWR Power Does not light up when no power is supplied Lights up green when the internal power supply PSU is functioning normally Lights up yellow when the internal power supply has failed and power is being supplied...

Page 64: ...t can be enhanced by a redundant port extension i e with two switches meaning that in the maximum configu ration 96 redundant LAN ports are available On the SE300 the port extension is possible if the Net Unit is redundant in design Further information on port extension is provided in the Additive Components Operating Manual 4 7 2 3 HNC High Speed Net Connect on the SE700 SE500 The High speed Netw...

Page 65: ...remote administration PCs see the information in the Quick Guide 7 This chapter describes the actions for switching these units on off which can be performed directly on the SE server SE300 as an alternative to switching it on off remotely Further information on this subject and also on the subjects IPL console and SE Manager is provided in the Operation and Administration manual 5 ...

Page 66: ...ruptly Notify Customer Support If despite the emergency there is still time enough you can also switch off Server Unit s Application Unit s and Management Unit manually via the operating panel at the front of the unit for the MU see figure 10 on page 49 and for the SU and AU see the Server Unit x86 3 and Additive Components Operating Manuals 4 Optional hardware compo nents have their own On Off sw...

Page 67: ...m 11 in figure 10 on page 49 lights up orange POWER STAND BY Ê Switch on the rack console by pulling out and folding out the monitor see page 31 Ê Press the On Off switch on the MU item 12 in figure 10 on page 49 The power on indicator lights up green The MU switches itself on conducts a system test and starts the M2000 software This takes a little time Finally on the rack console you see the logi...

Page 68: ...ed for XenVMs these systems are also started i The controls and indicators of the Server Unit are described in the Server Unit x86 Operating Manual 3 Further optional Server Units are switched on in the same way 4 Switch on the optional Application Units Before an Application Unit is switched on the status indicator lights up orange POWER STAND BY Ê Switch on the Application Unit by pressing the O...

Page 69: ...r at least four seconds Alternatively as the administrator you can switch the Application Unit off using the SE Manager menu Hardware Server SE model Units tab Switch off function see the Operation and Administration manual 5 i The controls indicators and further on off options for the AU are described in the Additive Components Operating Manual 4 Further optional Application Units are switched of...

Page 70: ...ator lights up green and after it has been switched off it lights up orange item 11 in figure 10 on page 49 Check this before continuing 4 Switch off the optional hardware components Ê Switch off the ETERNUS LT40 S2 tape library using the On Off switch on the front see the Additive Components Operating Manual 4 Ê Switch off any other connected hardware components i The ETERNUS JX40 disk storage sy...

Page 71: ...500 comply with the relevant safety regulations for IT equipment including electrical office equipment In an emergency the devices must immediately be switched off e g when the housing or power cable is damaged or liquid or foreign material gets into the equipment This can be done by pressing the POWER STAND BY button on the server s control panel or by pressing the UNIT EMERGENCY switch Pressing ...

Page 72: ...Switching the SE700 SE500 on and off Switching the server on and off 72 U41858 J Z126 1 76 Figure 25 UNIT EMERGENCY switch on the SE700 or SE500 SE700 SE500 basic rack SE700 SE500 with extension rack ...

Page 73: ...ing the SE Manager is provided in the Operation and Administration manual 5 The following hardware components must be switched on in the specified order 1 Switch on the optional hardware components Ê Switch on the ETERNUS LT40 S2 tape library using the On Off switch at the front see the Additive Components Operating Manual 4 Ê Switch on any other connected hardware components USB relay FST access ...

Page 74: ... switch on the MU remotely via the iRMC of the MU see the Operation and Administration manual 5 3 Switch on the Server Unit SU 390 Ê As the administrator or a privileged operator switch on the Server Unit using the SE Manager menu Hardware Server SE model Units tab Switch on function see the Operation and Administration manual 5 Alternatively you can switch the Server Unit on by pressing the POWER...

Page 75: ...rols and indicators of the Server Unit are described in the Server Unit x86 Operating Manual 3 5 Switch on the optional Application Units Before an Application Unit is switched on the status indicator lights up orange POWER STAND BY Ê As the administrator switch on the Application Unit using the SE Manager menu Hardware Server SE model Units tab Switch on function see the Operation and Administrat...

Page 76: ...is before continuing i If the operating system does not automatically switch off the Application Unit hold the On Off switch down for at least four seconds Alternatively as the administrator you can switch the Application Unit off using the SE Manager menu Hardware Server SE model Units tab Switch off function see the Operation and Administration manual 5 i The controls indicators and further on o...

Page 77: ...f the BS2000 system is shut down properly taking into account the remaining runtime specified Before the Server Unit is switched off the power on indicator lights up green and after it has been switched off it lights up orange Check this before continuing i The controls and indicators of the Server Unit are described in the Server Unit x86 Operating Manual 3 4 Switch off the MU Ê Switch off the MU...

Page 78: ...Switching the SE700 SE500 on and off Switching the server on and off 78 U41858 J Z126 1 76 ...

Page 79: ...to the greatest possible extent from environmentally friendly materials that can be fully recycled Read on through the next sections for a brief look at some of the measures we have introduced in an effort to protect the environment as well as our tips and suggestions for environmentally friendly handling of your system Environmentally friendly product design and development This product has been ...

Page 80: ... accordance with DIN EN ISO 14001 This also includes taking back your server and remarketing it or recycling it in an environmentally friendly manner To return your used server to FUJITSU please contact your sales representative or a branch of FUJITSU An offer will be submitted to you here or your server will be recycled free of charge at our remarketing and recycling center Service If you have an...

Page 81: ...ectrostatically Sensitive Device FC Fibre Channel HBA HostBus Adapter HDD Hard Disk Drive HNC High speed Net Connect HU Height Unit ID IDentifier iRMC Integrated Remote Management Controller ISDN Integrated Services Digital Network IP Internet Protocol IT Information Technology LAN Local Area Network LCD Liquid Crystal Display LED Light Emitting Diode LTO Linear Tape Open NMI Non Maskable Interrup...

Page 82: ...f Disks RMU Remote Management Unit RH Relative Humidity SAN Storage Area Network SAS Serial Attach SCSI SCSI Small Computer System Interface SU Server Unit SU 390 Server Unit 390 SU x86 Server Unit x86 USB Universal Serial Bus UPS Uninterruptible Power Supply ...

Page 83: ...ver BS2000 SE700 SE500 SE300 Basic Operating Manual 2 FUJITSU Server BS2000 SE700 SE500 Server Unit 390 3 FUJITSU Server BS2000 SE700 SE500 SE300 Server Unit x86 4 FUJITSU Server BS2000 SE700 SE500 SE300 Additive Components 5 FUJITSU Server BS2000 SE Series Operation and Administration User Guide 6 FUJITSU Server BS2000 SE Series Security Manual User Guide 7 FUJITSU Server BS2000 SE Series Quick G...

Page 84: ...Related publications 84 U41858 J Z126 1 76 ...

Page 85: ...DD FAULT 52 HDD SDD activity indicator 49 HDD SDD error indicator 49 HNC Open Source licenses 14 I ID button 49 ID indicator 49 50 51 53 indicators CPU fault 49 CSS 49 53 drive activity 49 51 Global error 49 53 hard disk activity 51 HDD SDD activity 49 HDD SDD error 49 ID 49 53 operating status indicator 49 server operating panel 44 storage fault 49 temperature fault 49 K keys server operating pan...

Page 86: ...ndicator 49 power supply unit 55 power on indicator 51 prompt symbol 12 R Reset button 49 50 S S server 14 SE server 21 architecture 22 security 15 17 Server Unit 21 shutdown 69 76 77 storage fault indicator 49 SU 390 13 SU x86 13 switching off 69 76 77 emergency 66 switching on 67 T temperature fault indicator 49 U upgrading 7 W warning signs 17 X X2000 10 Open Source licenses 14 ...