54
remain the same between modes, but the flow control changes. In the flash
update mode, the flow control changes to hardware flow control (RTS/CTS).
Once the system returns to normal operating mode, software flow control
(XON/XOFF) is used.
B.4
Update over Direct Serial Connection
The terminal or computer that will be used for the flash update must be
connected to the terminal port. All users must be logged out. The system
administrator must log in before beginning the update. Commands that the
administrator should enter and text returned by the ConsoleServer are in
Lucida
Console
font. All commands should be followed by
<ENTER>
.
sys admin>lciupdate
Start system update, are you sure? (write out "yes") "Yes" or "No": No>yes
Once there are no users logged in, the system administrator must type
LCIUPDATE
to initiate the flash update process. The ConsoleServer will ask the
system administrator if he is sure by displaying the prompt
Start system
update, are you sure? (write out "yes") "Yes" or "No": No>
.
If the system administrator wants to proceed with the update, he should type out
YES
completely and press
<ENTER>
. Otherwise,
NO
or just
N
and
<ENTER>
will
exit the process.
sys admin>lciupdate
Start system update, are you sure? (write out "yes") "Yes" or "No": No>yes
ConsoleServer800 Boot V1.20
Copyright 2000 by Lightwave Communications, Inc. All rights reserved.
Identify Flash
Flash ID OK
Verifying Flash Image
Select download protocol - X for XMODEM, K for KERMIT:
When using XMODEM, this prompt will be followed by the letter "C", which will
keep appearing on the screen, indicating the control card is ready to accept the
download.