6
3.3.2 DC
The DC version of the ConsoleServer 800 accepts standard –48 VDC telco
power. The ConsoleServer accepts two DC power inputs for supply redundancy.
See Appendix D for specifications regarding the DC power source.
DC power inputs
Installation:
Materials:
•
small
flat-blade
screwdriver
•
wire
stripper
•
ConsoleServer 800 DC power connector kit
•
wires to 48 VDC power (see Appendix D for specifications)
1.
Turn off the circuit breaker to the DC power supply.
2.
Select a three-wire set (-48V, –48 Return, and Power Supply Ground)
from the power supply.
3.
Strip 0.35 inches (89 mm) of insulation from each wire.
4.
Insert a small flat-blade screwdriver in the provided connector.
5.
Insert the appropriate wire into the connector. Remove the screwdriver.
6.
Attach the provided strain relief to the connector. Be sure to use a tie-
wrap to firmly attach the strain relief to the cable.