F-1021-0422
3-13
Electronic Acre Meter Kit -
Optional
Used with No Clutch, Basic Clutch or Console
w/Clutch Control
IMPORTANT
Acre Meter is dust and splash resistant, under no
circumstances should this unit be submerged in any
conductive, corrosive, or flammable liquid. At no time
use high pressure water or air to clean it, as this can
damage the unit.
Settings for Loup Acre Meters
The battery operated Acre Meter operates in one of two
modes.
1. In sleep mode, the display is blank, and the counter is
accumulating acres. Sleep mode will be entered if a
button is not pressed for 20 seconds.
2. In entry mode, the display is on, and the operator can
enter values. To get into entry mode, press the
*
/FUNC
button. If you continue to press the
*
/FUNC
button, the acre counter will cycle through the
functions that it can perform. The LEDs above the
display indicate which function is selected.
The available functions are:
Field Acres, Total Acres, Pulses per 400 feet, Width,
Password and Low Battery
Field Acres
Press the
*
/FUNC
button until the “
FIELD
” LED is lit. The
digits indicate the acres covered since the field acre
counter was cleared.
To clear the field acre count, press the
UP
and
DOWN
buttons simultaneously for two seconds. If a password
has been entered, you will not be able to clear the total
acre count. Field acres will count in tenths of an acre up
to 9999.9 acres.
Total Acres
Press the
*
/FUNC
button until the “
FIELD
” and “
TOTAL
”
LEDs are lit. The digits indicate the acres covered since
the total acre counter was cleared.
To clear the total acre count, press and hold the
UP
and
DOWN
buttons for two seconds. If a password has been
entered, you will not be able to clear the total acre count.
Total acres will count from.1 to 99999 acres.
Pulses Per 400 Feet
Press the
*
/FUNC
button until the “
PULSES
” LED is lit.
The number in the display indicates how many pulses are
generated for every 400 feet driven. There are two
methods to enter the pulses per 400 feet:
1. If you know the number, select it using the
UP
and
DOWN
buttons. When you press the
*
/FUNC
button,
the Acre Counter will accept the number in the display
as the new pulses per 400 feet.
.
2. If you Do not know the pulses per 400 feet, press and
hold the
UP
and
DOWN
buttons until the “0” appears
in the display. The “
PULSES
” LED will blink. The acre
counter is now counting shaft rotations. Enter the cab
and drive 400 feet. Press the
*
/FUNC
button to wake
up the acre counter. The “
PULSES
” LED will light.
The number displayed is the pulses per 400 feet.
Press the
*
/FUNC
button to accept the setting.
If a password is set, you will not be able to adjust the
pulses.
Width
Press the
*
/FUNC
button until the “WIDTH” LED is lit.
The number displayed is the length of your implement in
feet.
To adjust the width, press the
UP
and
DOWN
buttons. If
a password has been entered, you will not be able to
adjust the width.
The width can be adjusted from .1 to 99.9 feet, in tenths
of a foot.
Password
The password function allows you to protect the total
acre count, pulses per 400 feet, and width settings with a
password. This stops anyone from accidentally changing
those settings. When the acre counter is shipped, the
password is disabled. You can modify the pulses per 400
feet and implement width at any time.
Press the
*
/FUNC
button until the “
PASS
” LED is lit. The
digits will display the word “
Ent
” or “
dIS
”.
If the display shows
“dIS”
. The password is disabled.
The total acre count, pulses/400 feet, width, and
password settings can be adjusted using the
UP
and
DOWN
buttons. The password can also be changed
using the
UP
and
DOWN
buttons.
If the display shows “
Ent
”: You must enter your password
using the
UP
and
DOWN
buttons. When your password
is displayed, press the
*
/FUNC
button to test the
password. If the password is correct, you will be able to
change the acre counter settings. The password will be
viewable until the acre counter powers down. When the
acre counter is powered up again, you will have to
re-enter the password to change settings.
If the password is not correct, you will not be able to
change the acre counter settings. When the “
PASS
”
function is selected again, “
Ent
” will appear in the
display.
Содержание Brillion SS16
Страница 4: ......
Страница 8: ...iv F 1021 0422 TABLE OF CONTENTS ...
Страница 18: ...1 10 F 1021 0422 TABLE OF CONTENTS Table provided for general use NOTES ...
Страница 35: ...F 1021 0422 2 17 TABLE OF CONTENTS Table provided for general use NOTES ...
Страница 78: ...3 20 F 1021 0422 TABLE OF CONTENTS Table provided for general use NOTES ...
Страница 96: ...5 10 F 1021 0422 TABLE OF CONTENTS Table provided for general use NOTES ...
Страница 98: ...6 2 F 1021 0422 TABLE OF CONTENTS Table provided for general use NOTES ...