Glossary UH50 – FOR INTERNAL USE ONLY!
Gyr GmbH
Glossary UH606-101b
Page
5
of
38
F8 F1, F2, F3, F5 or F6 for 8 hours (unless F0, F4, F7 or F9 has been detected)
- Response as for F1/F2
F9 Internal communication between ASIC and µC defective
- Response as for “hard F0”
The occurrence of an error is recorded in a
logbook
(“occurrence” and “back to normal”). This
does not apply to F4 and F7, because in these cases the EEPROM is blocked for write access.
A negative flow or negative temperature difference is displayed correctly (is not treated as
missing time
).
Within limits, software errors can be rectified by means of an internal bugfix mechanism.
EU directive conformity declaration
The following text has been included in the Operating Instructions (not the Configuration
Instructions or the Installation and Service Instructions):
Gyr hereby declares that this
product complies with the essential
requirements of the following directives:
−
2004/22/EC
measuring instruments
directive
−
89/336/EEC
electromagnetic
compatibility of electrical and electronic
devices
−
73/23/EEC
low-voltage-directive
EC type examination certificate
DE-06-MI004-PTB018
EC design-examination certificate
DE-07-MI004-PTB010
Factory-fitted sensors
If sensors are fitted in the factory, the cable must not be disconnected, shortened, or extended.
“Fast pulses”
for the
pulse module
are parameterized using the PappaWin software.
When fitting with modules, please pay attention to the permissible
combinations
.
By default,
standard pulses
are output through the pulse module.
100%
Gradient
n-min
n-max
F