Glossary UH50 – FOR INTERNAL USE ONLY!
Gyr GmbH
Glossary UH606-101b
Page
31
of
38
−
T
R
> threshold value --> tariff 1
−
T
R
< threshold value --> tariff 2
Calculation of the quantity of heat is performed based on the “return temperature difference
from the threshold value” instead of the temperature difference between the flow and return.
Tariff register
Content
TR1
Quantity of heat for “upper” range
TR2
Quantity of cold for “lower” range
Display of the tariff status is identical to “
tariff control by means of threshold values
”.
The
tariff display
shows the current tariff and its status.
Display of the tariff
status
Display of the type of tariff
Display of the
tariff values
T2: Threshold value tariff using flowrate threshold
T3: Threshold value tariff using heat power threshold
T4: Threshold value tariff using return temperature threshold
T5: Threshold value tariff using flow temperature threshold
T6: Threshold value tariff using temperature difference threshold
T7: Tariff recording using supplied quantity of heat
No status display
T8: Tariff recording using returned quantity of heat
No status display
T9: Tariff recording using combined cold/heat meter