Glossary UH50 – FOR INTERNAL USE ONLY!
Gyr GmbH
Glossary UH606-101b
Page
35
of
38
Measured quantity of heat,
alternating with the simulated volume
Return to normal mode is performed automatically after no more than 15 hours.
Test mode temperature
The temperature difference (or the return temperature) is displayed with a resolution of 0.01 °C.
The average of, for example, 640 temperature measurements is evaluated (parameterizable).
Each update of the display value is indicated by brief display of an arrow symbol on the LCD.
Measured temperature difference (or return temperature)
Return to normal mode is performed automatically after no more than 15 hours.
Test mode volume
The flowrate measurements are performed in a measurement timebase of 250 ms. Pulses
proportional to the volume are output via the optical interface.
The accumulated volume is displayed with a resolution of 0.00001 m³ (10 ml). Each update of
the display value is indicated by brief display of an arrow symbol on the LCD.
Measured volume
Return to normal mode is performed automatically after no more than 15 hours.
Timers
The timers for the
operating
time
and the
missing time
are increment in the internal
hourly timebase.
The
flowrate measuring
time
is incremented with
each flowrate measurement
also in the internal hourly
timebase.
The format for output in the
telegram and on the LCD
can be parameterized for all
timers together (hours or
days).
&
&
Int. clock
1 hour
Flow
measuring
interval
Error
pending
Nb &
"Detected
flowrate"
Operating time
Missing time
Flowrate measuring
time
Lö_B
Lö_F
Lö_D
Ou
tp
ut for
m
at: h
our
s
or
da
ys
Telegram
Telegram
Telegram
LCD
LCD
LCD
The meter readings can be reset via telegram or in the parameter setting menu, currently, singly
or all together.
Function: Called
by...
Lö_B
Lö_F
Lö_D
“Master Reset” (all counter registers
and prescalers)
Telegram
x x x
“Reset times”
Telegram
x x x
“Reset operating time”
Telegram
x x x
“Reset missing time”
Telegram
x
“Reset missing time”
Parameter setting menu
x x
The
operating time
is
- always
summated
- reset – together with the
missing time
and der
flowrate measuring time
– with the
telegrams “master reset”, “reset times” and “reset operating time”
The
missing time
is
- summated, if an error is pending that prevents recording the quantity of heat.
- reset – together with the
operating time
and der
flowrate measuring time
– with the
telegrams “master reset”, “reset times“ and “reset operating time”
- reset – singly – with the telegram “Reset missing time”
- reset – together with the
flowrate measuring time
– im
parameter setting menu