To replace the auger motor via the snap
ring:
1. Unplug the dispenser.
2. Disconnect the wires to the ice chute
lever switch.
3. Remove the ice chute by prying the ice
chute pivot arms and pulling the
lever/chute out from the bottom of the
dispenser.
4. Remove the front splash panel.
5. Use a Phillips screwdriver to remove
the two screws holding the agitator
motor cover plate.
6. Unplug the agitator motor wiring
harness.
7. Use a Phillips screwdriver to remove
the screws from the auger motor
retaining bracket.
8. Remove the snap ring securing the
motor to the auger shaft using a snap
ring pliers.
9. Pull motor out.
10.Insert new auger motor and install new
snap ring using snap ring pliers.
11. Reinstall retaining bracket, plug in
motor, install cover plate, splash plate,
and ice chute.
12.Return unit to operation.
Note:
This process is very difficult as the motor
shaft must be aligned with the auger.
Note:
Square key is loose on the motor shaft.
Содержание BEVARIETY MCY-22
Страница 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Страница 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Страница 38: ...38 28 0724 02 3 6 Remote Pump Assembly 9 19 10 11 5 20 21 14 4 16 13 6 2 15 18 3 7 5 17 8 1 12 20 ...
Страница 49: ...49 28 0724 02 Notes ...
Страница 69: ...69 28 0724 02 Notes ...
Страница 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Страница 86: ...86 28 0724 02 ...
Страница 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Страница 90: ......
Страница 91: ......
Страница 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Страница 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...