![background image](http://html1.mh-extra.com/html/lancer/bevariety-mcy-22/bevariety-mcy-22_installation-and-service-manual_3500568084.webp)
84
28-0724/02
6.10
Ice Delivery System
The unit comes equipped with the standard ice handling mechanism found on the 4500 series
ACIB dispenser. Agitator/wheel assembly breaks up ice bridging and delivers ice to chute
assembly. A snap action switch activated by the ice lever provides power to the auger motor.
This is a DC controlled switch that interrupts the power to the board to activate the motor.
6.11
Ice Board Settings
Each ice beverage dispenser is equipped with automatic agitation for the ice bin. The
unit is shipped with timing set at two seconds ON every sixty minutes. Referring to the
tables on the wiring diagram included in this manual (also affixed to the electrical box
cover), the automatic agitation timing can be changed as follows. A set of DIP switches
is provided to control the timing and low ice control.
1. DIP#3 & #4
These switches control the ON time for automatic agitation. By referring to the table
and setting the switches as shown, ON times from one (second to four seconds [in one
second increments] can be obtained. EXAMPLE: For three seconds ON time, switch
3 should be in the ON position, and switch 4 should be in the OFF position. The unit is
shipped with two seconds ON time.
Automatic Agitation
The dispenser is equipped with automatic agitation. It may
activate unexpectedly. Do not place hands or foreign objects
in the ice storage compartment. Unplug dispenser from the
power source when it is being serviced, cleaned, or
sanitized.
Содержание BEVARIETY MCY-22
Страница 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Страница 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Страница 38: ...38 28 0724 02 3 6 Remote Pump Assembly 9 19 10 11 5 20 21 14 4 16 13 6 2 15 18 3 7 5 17 8 1 12 20 ...
Страница 49: ...49 28 0724 02 Notes ...
Страница 69: ...69 28 0724 02 Notes ...
Страница 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Страница 86: ...86 28 0724 02 ...
Страница 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Страница 90: ......
Страница 91: ......
Страница 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Страница 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...