![background image](http://html1.mh-extra.com/html/lancer/bevariety-mcy-22/bevariety-mcy-22_installation-and-service-manual_3500568018.webp)
18
28-0724/02
30” With MVU
30” Without MVU
2. Connect remaining syrup lines to the left side of the dispenser. On the 30” unit,
syrups 9-12 and the ambient syrups are only used if an MVU is present. Syrups
7-8 and the ambient syrups on the 22” unit are only used if an MVU is present.
1.11
CONTINUINg THE INSTALLATION
Confirm that all configurable valves are set to the correct carb/non-carb option. Refer to section
4.18 for the procedure. The configurable valves are valves 2-5 on the 22” without an MVU and
valves 3-6 on the 30” without an MVU.
1. Install tubular insulation onto the drip tray drain fitting. Insulation should sit flush
against the back of the drip tray. Insulation has a 5/8” ID with a 3/8” wall and is 3/4”
thick:
2. Extend hose to open drain.
3. Install drip tray onto base unit.
Drip Tray
Tubular Insulation
PN 88-0057
Drip Tray Drain Fitting
Содержание BEVARIETY MCY-22
Страница 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Страница 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Страница 38: ...38 28 0724 02 3 6 Remote Pump Assembly 9 19 10 11 5 20 21 14 4 16 13 6 2 15 18 3 7 5 17 8 1 12 20 ...
Страница 49: ...49 28 0724 02 Notes ...
Страница 69: ...69 28 0724 02 Notes ...
Страница 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Страница 86: ...86 28 0724 02 ...
Страница 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Страница 90: ......
Страница 91: ......
Страница 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Страница 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...