4. Drain line must be insulated with a closed cell insulation. Insulation must cover the
entire length of the drain hose, including fittings. The drain should be installed in
such a manner that water does not collect in sags or other low points, as
condensation will form.
5. Install cup rest.
6. Connect power cord to grounded electrical outlet.
7. Test motor operation by pushing ice chute.
8. Clean and sanitize dispenser (see Section 2).
1.11
STARTUP PROCEDURES
1. Turn on water to carbonator pump:
2. Open the relief valve on the carbonator to purge air from the system. Keep open
until water comes out of relief valve.
3. Close relief valve.
4. Activate all valves until a flow of plain water is established from each valve.
5. Turn on CO2 at source and ensure the high pressure regulator is set at 75 PSIG.
6. Empty the carbonator tank by activating a valve until no water comes out.
7. Plug in the carbonator pump motor. The pump will cycle for 5.5 seconds, shut down,
and start again. It will run for additional 5.5 second intervals until the water level
reaches the probe.
8. Activate the carbonated water valves so that the carbonator pump cycles several
times and a healthy flow of carbonated water is established.
Plain water to unit
Soda (carbonated) water to unit
Remote carbonator pump deck
Plain water tee
Water source
Relief Valve
CO2 Inlet Fitting
Содержание BEVARIETY MCY-22
Страница 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Страница 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Страница 38: ...38 28 0724 02 3 6 Remote Pump Assembly 9 19 10 11 5 20 21 14 4 16 13 6 2 15 18 3 7 5 17 8 1 12 20 ...
Страница 49: ...49 28 0724 02 Notes ...
Страница 69: ...69 28 0724 02 Notes ...
Страница 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Страница 86: ...86 28 0724 02 ...
Страница 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Страница 90: ......
Страница 91: ......
Страница 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Страница 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...