background image

Thank you for purchasing your Liff Limebeater. 
Following the installation instructions below will 
ensure this product performs as specified.

There are eight Limebeater models:

 

LBC2-15V2,  

LBC2-22V2, LBC28, LBC35, LBC42, LBC54 and LBP2-15, 
LBP2-22. The Numerals after the LBC and LBP indicate the 
size of pipe fitting connections supplied.

  Step 1

Turn off the water feeding the section of the pipe where you 
wish to install the Limebeater.

  Step 2

Drain the pipe-work if required.

  Step 3

Select a suitable section of straight pipe and using the 
Limebeater body as a measure cut out a piece of pipe. 
Cut the pipe square, ensuring it is free of score marks, 
burrs and sharp edges. Support Limebeater either side of 
installation with appropriate brackets.

  Step 4 

Compression fittings only

1.

 With the section of pipe removed, unscrew the nuts and 

remove the olives from either end of the Limebeater and 
slide them onto either end of the remaining pipework.

2.

 Ease pipe apart and insert Limebeater between cut 

sections of pipe.

3.

 Push each end of the existing pipework into the 

Limebeater body until it is touching the internal stop.

4.

 Tighten up the nuts to make a water tight seal on  

the olives.

  Step 5

 

Push-fit fittings only

1. 

Gently push both ends of the existing pipework into the 
Limebeater body until it touches the internal stops. The 
collet has stainless steel teeth which grip the pipe whilst 
the ‘0’ ring provides a leak-proof seal.

2. 

At this point the connection is gripped but not sealed. Pull 
the pipe to check it is secure, which also makes the seal.

  Note:

Do not insert fingers into fitting as the stainless steel teeth
incorporated within the collet may cause injury.

  Step 6

 

Disconnecting a fitting

1. 

Ensure system is depressurised before removing fitting.

2.

 Push in collet squarely against face of fitting. With 

the collet held in this position, the pipe can be easily 
removed. The fitting can then be re-used.

  Step 7

Installing isolating valves either side of the Limebeater 
will facilitate the easy removal and replacement of the 
Limebeater should the need arise. Please remember that the 
pipe work either side of the Limebeater must be supported 
by bracketing.

  Step 8

Turn the water back on and check for leaks.

NB. 

When fitting a Limebeater product, please ensure that 

your installation complies with local plumbing codes and 
practices.

Do not use a wrench or stilsons on the Limebeater 
body as this will damage the casing.

Installation instructions

Limebeater Installation Instructions_v3.indd   1

26/03/2013   14:16

Reviews: