![background image](http://html1.mh-extra.com/html/lancer/bevariety-mcy-22/bevariety-mcy-22_installation-and-service-manual_3500568076.webp)
76
28-0724/02
6.4
Carbonation System
The carbonating system consists of the following components:
•
Electrode
- When the water level in the carbonator tank falls below the tip, the liquid
level control turns on the pump motor for 5.5 seconds. If the water level does not reach
the tip, the motor continues to run in 5.5 second intervals until the water touches the
tip. Once the water reaches the tip, the motor will stop running at the end of the 5.5
second interval. The black wire and the green (ground) wire complete the circuit inside
the tank.
• Picture Frame Carbonator Tank
(embedded in cold plate - 131 oz capacity)
•
CO
2
Check Valve
- Prevents carbonated water from backing into the CO
2
system.
•
Backflow Preventor
- Prevents carbonated water from backing into building's water
supply.
•
Relief Valve
- Vents the carbonator when pressure exceeds 240 psig.
Carbonator Pump
- Consists of the following components:
•
Pump Motor
- Standard 1/3 hp motor
•
Water Pump
- Standard 100 GPH 250 psig bypass
• Liquid Level Control
- Operates as a timer. When liquid level drops below the probe
tip, the control turns on the carbonator pump motor for 5.5 seconds and then shuts off.
The liquid level control will time out after 3 minutes of cycling on and off if probe fails. A
light on the liquid level control will blink as well.
Содержание BEVARIETY MCY-22
Страница 28: ...28 28 0724 02 3 Illustrations and Parts Listings 3 1 Decals and Labels 1 1 2 3 4 5 6 6 7 7 ...
Страница 30: ...30 28 0724 02 3 2 Final Assembly Post Mix IBD and Ice Dispenser ...
Страница 38: ...38 28 0724 02 3 6 Remote Pump Assembly 9 19 10 11 5 20 21 14 4 16 13 6 2 15 18 3 7 5 17 8 1 12 20 ...
Страница 49: ...49 28 0724 02 Notes ...
Страница 69: ...69 28 0724 02 Notes ...
Страница 70: ...70 28 0724 02 5 3 MVU Assembly 3 4 5 6 7 8 9 10 11 12 13 14 5 ...
Страница 86: ...86 28 0724 02 ...
Страница 89: ...89 28 0724 02 6 13 Dispenser Connections Valve Map Summary CO2 Water and Syrup ...
Страница 90: ......
Страница 91: ......
Страница 92: ...92 28 0724 02 6 16 22 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...
Страница 93: ...93 28 0724 02 6 17 30 Bevariety ACIB Wiring Plumbing Diagram 115V 60Hz ...