background image

Manual 

 Barista Milk Mate 1.5 

 
© La Cultura Del Caffè GesmbH 

04.09.2015 

Page 1 | 36 

 
 
 
 

Barista 

Milk Mate 

 

 

Manual

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

© La Cultura Del Caffè GesmbH, subject to change without notice - errors and omissions excepted 

Summary of Contents for Barista Milk Mate

Page 1: ...Manual Barista Milk Mate 1 5 La Cultura Del Caff GesmbH 04 09 2015 Page 1 36 Barista Milk Mate Manual La Cultura Del Caff GesmbH subject to change without notice errors and omissions excepted...

Page 2: ..._________________________________ 14 3 9 1 4 Language ______________________________________________________ 14 3 9 1 5 Display ________________________________________________________ 15 3 9 1 6 Disp...

Page 3: ...__________________________________________________________ 30 4 4 2 Display ____________________________________________________________ 31 4 4 3 Operation ____________________________________________...

Page 4: ...nfiguration is supplied to conveniently configure the controller unit All necessary configurations can also be made directly at the controller unit via a service menu The configuration of the device i...

Page 5: ...ply 2 2 Connection of the supply For supplying the device only direct current DC in the range of 12 24VDC may be used This voltage is also used to supply the valves 2 3 Connection of the valves Common...

Page 6: ...ct a cash register via the optionally supplied serial RS 232 cable 9 pole SUB D The connector at the cable is wider than the connector at the electronics board to make it impossible to connect it reve...

Page 7: ...a Milk Mate is switched on by connecting the power supply unit to the power grid 3 3 Standby The standby screen shows the chosen picture menu Settings Standby image Normally the standby screen is show...

Page 8: ...f a portion only starts if the cash register allows the request In the meanwhile the button is shown as being pressed but without the Play sign mentioned above If the cash register denies the request...

Page 9: ...own at the bottom edge of each button to show the actual report counter for that button portion It is shown as long as the screen is touched again to return to the usual desktop screen 3 5 Code input...

Page 10: ...s shown Reporting shows the report counters for each button portion The Event memory displays chronologically different events Settings is used to configure the device The Service menu is used for som...

Page 11: ...button Reset counter will become active if at least one counter is chosen to be reset After pressing the button Reset counter a new pop up window appears to either confirm or cancel the procedure If t...

Page 12: ...an entry by touching it If details are stored for the selected event the button Details is activated to allow the user to see further detailed data Events with additional details are Date time change...

Page 13: ...ow 3 9 1 General This submenu is used to adjust the login code the backlight and standby timeout the language and the display options see the according parameters in the configuration program 3 9 1 1...

Page 14: ...ing the button or cancel using the button X in the title bar 3 9 1 3 Standby timeout In this submenu the parameter Standby timeout may be changed either via direct entering a number using the digits 0...

Page 15: ...d of 3D effect by getting darker towards the bottom If not the buttons appear flat single color Confirm using the button or cancel using the button X in the title bar 3 9 1 7 Display Title bar Use thi...

Page 16: ...or cancel using the button X in the title bar Text color of the title bar Use one of the 15 colored buttons to preselect a color By using the 3 fields below those buttons it is possible to adjust eac...

Page 17: ...cel using the button X in the title bar 3 9 2 Operation A list of all configurable operation parameters is shown All parameters which can be found in the configuration program see General settings Ope...

Page 18: ...y come from the configuration program are shown After a text is chosen so that it is marked it is possible to edit it by touching the button The screen for text editing appears The button at bottom le...

Page 19: ...standby screen The navigation between all available pictures is done with the buttons and If the picture of interest is reached confirm the selection using the button or cancel using the button X in t...

Page 20: ...sequence 2 is started By pressing the Test button the actual portion is dispensed for verification purposes Confirm and store the new portion using the button or cancel using the button X in the titl...

Page 21: ...on set the text color of the button set the font size of the button text Confirm using the button or cancel using the button X in the title bar Background color and text color of the button The screen...

Page 22: ...ancel using the button X in the title bar 3 9 7 Date time At first you can see date and time when this menu was entered Use the buttons and to adjust the data Confirm using the button or cancel using...

Page 23: ...tion is dispensed immediately If type is set to CSI an inquiry at the cash register is started after a portion is requested only if the cash register allows the portion to be dispensed this action is...

Page 24: ...d possibly harm the touchscreen foil 3 10 2 Display test This menu is used to test if the display works properly in fact to test the touchscreen input and the color rendering Touch inputs It is possib...

Page 25: ...drivers and the connected valves By pressing a valve button the according valve is activated powered and the button appears red By pressing the button again the valve is deactivated and the button be...

Page 26: ...hey were erroneous or not Byte errors Parity Framing The amount of erroneously received data bytes is shown the sum of parity framing and break errors Byte errors RxBuffer overflow The number of bytes...

Page 27: ...the button Clear databuffer a new pop up window appears to either confirm or cancel the procedure ATTENTION When clearing the databuffer the report counters and the event memory are DELETED PERMANENTL...

Page 28: ...ely in the general settings Device language 4 1 1 File format This program uses a proprietary file type with ending mmcfg After installation files with that ending can directly be opened with this con...

Page 29: ...he device 4 2 3 Readout The configuration general settings images and text as well as button design and portions is read out from the device 4 2 4 Send time Send current date and time to the device in...

Page 30: ...ed for entering the menu on the device see chapter 3 5 In fact there is a default value for this PIN code which is created when starting a new file but it can be changed at any time By doing so the co...

Page 31: ...be discarded Aborting possible Defines if the portions can be aborted regardless of whether they are paused View reports without login Here you can adjust if the reports can be displayed directly on...

Page 32: ...number is used for the mapping on the device In the column Standby you can define which image shall be displayed on the standby screen Only one can be chosen a multiple selection is prevented here ATT...

Page 33: ...Manual Barista Milk Mate 1 5 La Cultura Del Caff GesmbH 04 09 2015 Page 33 36 When the mouse is moved over a thumbnail the related image is displayed in original size within a pop up window...

Page 34: ...pping on the device ATTENTION Every single text must have a unique number Therefore repeated usage of the same number is already prevented when typing The following functions are available via the but...

Page 35: ...and its font size can be set for the title bar on the device s desktop Background For the desktop screen the background color can be adjusted ATTENTION The color selected here will also be used in th...

Page 36: ...24VA 100 ED Max valve power 24VDC 48VA 100 ED Cash register interface CSI RS232 1200 57600bps 8 data bits no parity 1 stop bit Ambient temperature Frost free min 5 C max 50 C Humidity maximum 90 rH n...