background image

Table of Contents

Declaration of Conformity 

2

Association 

2

Recommendations for Safeguarding the 

Environment 

3

Explanation of Warning/Safety Icons 

3

Introduction 

4

Components Guide 

5

Product Specifications 

6

Before You Begin – Requirements for 

Installation 

7

Mounting Dimensions 

7

Operating Environment 

8

Water 

8

Electrical 

8

Tools You Will Need 

9

Unpacking the Kit 

9

What’s in the Kit 

10

Installing the Machine 

11

Operating the Keypad 

16

Routine Maintenance 

17

Troubleshooting 

20

Replacement Parts 

23

NOTICE:

 

Read the instructions in this manual and retain for future reference.

Installation and 

Maintenance 

Manual

ENERGY

SAVING

DSBS130UVPC

DSBSH130UVPC

Summary of Contents for DSBS130UVPC

Page 1: ...u Begin Requirements for Installation 7 Mounting Dimensions 7 Operating Environment 8 Water 8 Electrical 8 Tools You Will Need 9 Unpacking the Kit 9 What s in the Kit 10 Installing the Machine 11 Operating the Keypad 16 Routine Maintenance 17 Troubleshooting 20 Replacement Parts 23 NOTICE Read the instructions in this manual and retain for future reference Installation and Maintenance Manual DSBS1...

Page 2: ...ctive 2006 95 EC O O the protection requirements of the Electromagnetic Compatibility Directive 2004 108 EC The electrical safety of the product is ensured only when it is properly connected to an efficient legally compliant grounding circuit UL standard for safety of drinking water coolers ANSI UL 399 Issued 2008 08 22 Ed 7 Rev 2013 10 18 CSA standard for refrigeration equipment CSA C22 2 No 120 ...

Page 3: ... should be taken to a dedicated recycling center for electrical and electronic equipment Immediately prior to scrapping cut off the power cable For more information on the treatment recovery and recycling of this product please contact the appropriate local office the waste disposal service or the reseller from which the product was purchased These products contain no CFCs or HFCs which contribute...

Page 4: ...cold sparkling water room temperature still water and or hot water O O Natural materials throughout stainless steel aluminum O O Internal components made entirely of stainless steel O O DRY COOLING technology a noiseless low maintenance and innovative cooling system which allows for great performance and compact size O O Made entirely of stainless steel O O Anti bacterial UV lamp at dispensing poi...

Page 5: ...rd Thermostat Cold sparkling dispenser Room temperature still dispenser Cold still dispenser DSBS130UVPC DSBSH130UVPC DSBS130UVPC keypad DSBSH130UVPC keypad Keypad Drip tray Boiler switch Power button Water inlet CO2 inlet Power cord Thermostat Cold sparkling dispenser Hot dispensers Cold still dispenser ...

Page 6: ... pipe ø 1 4 ø 1 4 Power 110V 60Hz 110V 60Hz Power consumption 200W 2A 1130W 9 4A Working room temperature Min 41 F Max 107 6 F Min 5 C Max 42 C Min 41 F Max 107 6 F Min 5 C Max 42 C UNIT WEIGHT lb kg 67 5 30 6 67 5 30 6 SHIPPING WEIGHT lb kg 72 32 6 72 32 6 Dimensions W x D x H in mm 10 26 x 19 23 x 16 44 261 x 488 x 418 10 26 x 19 23 x 16 44 261 x 488 x 418 Dispensing area height in mm 10 99 279 ...

Page 7: ...28 711mm Height 12 75 324mm Depth 3 88 99mm Diameter 8 203mm Width 3 25 83mm Footprint 10 3 wide x 19 2 deep 261mm x 488mm DSBS130UVPC DSBSH130UVPC Over counter includes 4 clearance on sides and back Under counter Water filter CO2 cylinder typical 20 pound Width 18 3 465mm Depth 23 2 589mm Height 20 5 520 7mm Footprint 10 3 wide x 19 2 deep 261mm x 488mm ...

Page 8: ...r cooler to a water main that supplies drinking water only O O Use of 1 4 diameter connections is recommended O O Turn off the main water inlet tap if the unit is not to be used for a long period Electrical O O Check that the voltage shown on the serial number plate corresponds to the voltage being supplied at the installation site O O Do not use extension cables or multiple power sockets The mach...

Page 9: ...nts to ensure that they are not damaged Contact the carrier immediately if there has been any damage during shipping NOTICE Ensure that your machine is installed by a qualified technician in compliance with the manufacturer s instructions and the local safety guidelines NOTICE Only qualified technicians should access the internal components of your machine 2 8 adjustable wrenches 1 10 adjustable p...

Page 10: ... 1 DSBS130UVPC or DSBSH130UVPC water cooler 1 CO2 regulator 1 external water filter 2 3 8 quick connect connector 1 supply hose 1 2 ips x 3 8 tube x 12 long 1 water shutoff valve 1 water pressure regulator 1 10 coil CO2 tubing natural 1 4 OD 1 3 8 x 3 8 quick connect connector 1 10 coil water tubing blue 1 4 OD 1 10 coil water tubing blue 3 8 OD PLUS ...

Page 11: ...t to under counter wall 2 Use 4 Phillips head screws to mount filter head to bracket 3 Remove cap from filter Insert filter into filter head and turn clockwise right until it stops When installing external water filler within the DSCABBSH cabinet please refer to the following mounting instructions 1 Use 3 Phillips head screws and washers to mount filter bracket to cabinet mounting strip as shown b...

Page 12: ...hine Water source threaded fitting Water source open 3 8 pipe Water filter 3 8 quick connect adapter 1 4 x 1 4 Water shutoff valve Water pressure regulator Water piping cut to size 1 4 Water tubing cut to size To water cooler Short 3 8 3 8 pipe Using the quick connect fittings To connect 1 Make clean 90 cut to piping end 2 Push piping straight into fitting until it stops 3 Pull back to check that ...

Page 13: ...to place 4 Connect external water and CO2 piping 5 Plug the machine into the wall socket and turn it on 1 Connect the power cable to the nearest socket 2 Flip the power switch at the rear of the machine A to the I position A B Water input Water input CO2 input CO2 input DSBS130UVPC DSBS130UVPC DSBSH130UVPC DSBSH130UVPC A B A B A B ...

Page 14: ...ever turn on the boiler unless you have filled the machine with water NOTICE Never turn on the boiler when the inlet water is disconnected 1 Flip the boiler switch at the rear of the machine to the I position 2 After around 10 minutes the water reaches the setted temperature CAUTION Hot water reaches 185 F Keep children away Hot boiling water and steam will scald if spilled on skin Do not touch th...

Page 15: ...ads 50 to 58 psi max 9 Re purge the line for sparkling water NOTICE The water will flow flat at first then gradually become more sparkling as the line is purged of still water 10 Allow machine to complete initial chilldown NOTICE Complete water heating will require around 10 minutes The machine should not be used as a water dispenser until heating is complete ...

Page 16: ... To stop dispensing your water serving Release the button for that dispenser Operating the Keypad DSBSH130UVPC To dispense your water serving Hold down the button for that dispenser Note For safety reason to dispense hot water you must press and hold down the 2 hot water buttons at the same time To stop dispensing your water serving Release the button for that dispenser ...

Page 17: ... to clean the product Metal fibers have a tendency to disintegrate and release small metal particles that are embedded in the surface Metal particles oxidize and give the impression that the surface of the product is rusting Do not use abrasive cleaners or abrasive pads as these will scratch the surface of the product Do not use a water jet O O To remove limescale use a slightly acidic product e g...

Page 18: ...ze the machine NOTICE This operation must be carried out by your ELKAY reseller or by a qualified technician When required O O Replace the UV lamp CAUTION The light emitted by the ultra violet lamp may cause serious burns to the eyes and skin Disconnect the electrical source of supply of the UV radiation before opening the machine 1 Disconnect the unit from its electrical source 2 Once the unit is...

Page 19: ...19 1000003719 Rev A 02 2017 O O Set the thermostat 1 Set the thermostat between 5 and 6 to control the temperature of the cold water COLDER OFF 1 2 3 4 5 6 7 ...

Page 20: ...e Cause Action To Take Sparkling water doesn t come out The CO2 cylinder is empty Replace the cylinder The pump is not working Force the pump to start Replace the pump if broken The solenoid is not working Repair or replace the solenoid The flow control valve is too tight Open the valve Problem Possible Cause Action To Take Water is not cold enough The thermostat is not adjusted properly Adjust th...

Page 21: ...2 tank Replace seal The CO2 exit pressure lower than 36 psi 2 5 bar Set the pressure between 55 60 psi 3 5 4 bar A reset is needed Turn the machine off and back on Problem Possible Cause Action To Take Only CO2 gas comes out when sparkling water button is pressed The pump runs for 4 minutes continuously Check why the water is not entering the unit and fix it The water valve is closed Open the valv...

Page 22: ...22 DSBS130UVPC and DSBSH130UVPC Installation and Maintenance Manual Contacting Customer Support Elkay Manufacturing Company 2222 Camden Court Oak Brook IL 60523 800 726 0553 ...

Page 23: ...000003895 Exit Solenoid Vavle hot x x 1000003896 Flow Control 6mm x x 1000003897 Flow CONTROL 8mm x x 1000003898 Transformer 110 24 x 1000002636 Lock with 2 Keys x x 1000002637 UV OUT Pipe x x 1000003901 UV OUT Inverter x x 1000003902 Blusoda DripTray and Grill complet Set x 1000003904 BOILER TERMODISK 87 x 1000003905 BOILER SAFETY TERMODISK 110 x 1000003906 BOILER EVO NO PRESSURE 1 Lt 1000W 110V ...

Page 24: ...160217 ...