19
TROUBLE
CAUSE
REMEDY
4.5 Water only dispensed; no syrup; or
syrup only dispensed, no water
A. Water or syrup shutoff on mounting
block not fully open.
B. Improper or inadequte water or syrup
supply.
C. BIB supply too far from dispenser
D. CO2 pressure too low.
E. Stalled or inoperative BIB pump.
F. Kinked line.
A. Open shutoff fully.
B. Remove valve from mounting block
and open shutoffs slightly. Check water
and syrup supply. If no supply, check
dispenser for freeze-up or other
problems. Ensure BIB connection is
engaged.
C. Check that BIB supply is within eight
feet (2.4 m) of the dispenser.
D. Check the CO2 pressure to the pump
manifold to ensure it is between 70-80
PSI (0.483-0.552 MPA)
E. Check CO2 pressure and/or replace
pump.
F. Remove kink or replace line.
4.6 Valve will not shut off.
A. Cup lever may be sticking or binding.
B. Switch not actuating freely.
C. Solenoid armature not returning to
bottom position.
A. Correct or replace lever.
B. Check switch fro free actuation.
C. Replace defective armature or spring.
4.7 Syrup only dispensed. No water, but
CO2 gas dispensed with syrup.
A. Improper water flow to dispenser.
B. Carbonator pump motor has timed out.
C. Blown fuse on circuit board.
D. Liquid level probe not connected
properly to PCB.
E. Faulty PCB assembly.
F. Faulty liquid level probe.
G. Water bath frozen.
H. Water line frozen.
A. Check for water flow to dispenser (see
Section 8.2)
B. Reset by turning the unit OFF and then
ON, by using the ON/OFF switch on top
of the unit, or unplugging unit
momentarily.
C. Check Fuse F1 on circuit board.
D. Check connections of liquid level
probe to PCB assembly.
E. Replace PCB assembly.
F. Replace liquid level probe.
G. Thaw water bath and repair faulty
component. (See refrigeration related
symptoms.)
H. See Section 8.11.
Содержание 605
Страница 25: ...25 NOTES...
Страница 28: ...28 5 2 MINIPUMP ASSEMBLY FIVE FLAVOR PN 82 3900 2 4 11 5 6 8 7 9 10 1 3...
Страница 30: ...30 5 3 FOAM TANK CABINET ASSEMBLY 10 7 8 5 6 18 19 12 13 17 14 15 16 2 11 9 3 4 1...
Страница 32: ...32 5 4 CARBONATOR WATER SYRUP LINE ASSEMBLIES 3 13 12 11 1 10 4 5 6 7 8 9 9 2...
Страница 36: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...