WARNING – Thermopro servers may be heavy when filled. 

Care must be taken when transporting to avoid dropping or spilling.

Use only coffee or water in the insulated dispenser. Do not use the ThermoPro server to dispense any 

other beverage. Preheating is recommended.
1.  Place a clean and empty server centered under one of the brewcones of your coffee brewer.
2.  Make sure the screen reads READY TO BREW.
3.  Fill brewcone with the correct measure of ground coffee for the intended volume of brewed coffee.
4.  Select the brew button that matches the brew volume and press to brew into the coffee dispenser.
5.  Allow coffee in the brewcone to drip completely before removing the insulated dispenser.

SERVICING THE THERMOPRO SERVER

1.  Completely drain the unit of any coffee. 
2.  Allow server to cool. 
3.  Unscrew and remove the lid and tube assembly. 

REPLACING THE GAUGE GLASS

The gauge glass can be removed for maintenance and cleaning. Refer to the illustration on page three [3] for assembly sequence.
1.  Unscrew the vented cap plug from the top of the gauge glass shield.
2.  Carefully lift out the gauge glass tube from the shield and scrub inside the glass with a tube cleaning brush and mild  

 

detergent solution. Inspect the glass tube for cracks or chips. If broken, carefully remove all traces of glass and then insert    

a new gauge glass tube. 

3.  Check the top and bottom washers that make the tube water tight. Clean the washers. Make sure they are not leaking.  

 

Replace if necessary. 

4.  With the sight glass seated in the gauge glass shield, thread the cap plug onto the top of the shield. Do not overtighten.

REMOVING THE BASE & BOTTOM COVER

To replace the silicone elbow fitting for repair or cleaning:
1.  Remove the base assembly. Press down on the slide tab on the back side of the stand and lift off the  

 

server section.

2.  Turn the server upside down and take off the plastic bottom cover. This will reveal the silicone elbow  

 

fitting. 

3.  Remove the wire hose clamps by squeezing the wire ears together. While holding the clamp open,  

 

loosen the soft silicone elbow from the liner drain pipe and the faucet shank and pull out elbow.

4.  Check for leaks and replace with a new part if necessary.
5.  Reverse these steps to assemble.

REMOVING THE FAUCET

The faucet will require periodic cleaning and maintenance.
1.  Remove the faucet from the body of the server. Unscrew the large nut holding the faucet to the shank to    

take off faucet.

2.  Disassemble the faucet. Unscrew the bonnet from the body of the faucet.
3.  Remove the faucet handle by pressing inward on the seat cup (see photo at right) then unhooking the    

handle from the center shaft.

4.  The seat cup, center shaft and spring will now separate from the bonnet. Clean these parts with a mild    

detergent solution.

5.  While you have these parts disassembled for cleaning, check the seat cup for tearing of splitting. Make sure 

the faucet spring is free of corrosion. Replace these parts with repair kit if necessary (item 15, page 3).

ASSEMBLY

Assemble the unit by reversing the steps for disassembly. Finger tighten wing nut onto faucet. Make sure clamps are fastened prop-

erly and silicone fittings are in good condition. Once assembled, check for leaks around the fitting and faucet.

W

ilbur

 C

urtis

 C

ompany

, i

nC

.

Service Manual – TXSG Server

Содержание ThermoPro TXSG0101S600

Страница 1: ... seated in the gauge glass shield thread the cap plug onto the top of the shield Do not overtighten REMOVING THE BASE BOTTOM COVER To replace the silicone elbow fitting for repair or cleaning 1 Remove the base assembly Press down on the slide tab on the back side of the stand and lift off the server section 2 Turn the server upside down and take off the plastic bottom cover This will reveal the si...

Страница 2: ... the filling tube c Rinse with clean water 3 Cleaning and sanitizing body assembly a Partially fill the insulated server with cleaning solution Use a sponge brush to thoroughly clean inside liner b Rinse the unit using a fresh water rinse c Pour sanitizing solution into the insulated server Allow to sit for 5 minutes then drain through the faucet d Rinse by pouring water inside the unit allowing r...

Страница 3: ...8 TLXSG10 TOP SERVER THREADED BLK BRACKET GAGE GLASS RING SHIELD GAGE GLASS 10 TLXSG15 SHIELD GAGE GLASS 8 TLXSG10 NUT FLANGED PLASTIC SHANK PLASTIC WASHER 188 ID X 188 THK BTM SHIELD BASE GAGE GLASS BLACK NUT WING PLASTIC 1 1 32 14UNF C RING 917 x 760 x 090 KIT FAUCET REPAIR 16 17 18 19 20 21 22 22A 23 24 25 26 27 28 29 30 WC 1841 WC 29082 WC 64079 WC 43091 WC 2456 WC 58262 WC 56020 WC 56013 WC 6...

Страница 4: ... This equipment must be installed by a professional technician and must comply with all local electrical mechanical and plumbing codes 3 Improper voltage Equipment must be installed at the voltage stated on the serial plate supplied with this equipment 4 Improper water supply This includes but is not limited to excessive or low water pressure and inadequate or fluctuating water flow rate 5 Adjustm...

Отзывы: