16
an effect in Emem 25 for example, register 025 will be recalled on the TDC when you
recall that effect. If you send a Trigger 11 from within that effect, register 125 will be
recalled. If you send a Trigger 12 register 225 will be recalled.
Note that these recalls are just like normal register recalls, in that they affect all
channels. Most triggers affect only machines which have valid device numbers, or
are ganged. These do not – they recall the registers regardless of device numbers.
Only machines which have valid inpoints and valid device numbers will be cued.
All 300 registers are directly accessible from P-bus, if the switcher supports this
expanded access. This may make the use of SELECT BANK triggers unnecessary.
The other triggers are 8 and 9, which are related to Multi-Point Loops. Please see
the detailed operational information section for an explanation of these triggers.
SIMULATING P-BUS TRIGGERS FROM THE CONTROL PANEL
P-bus triggers 0-9 may be simulated from the keypad of the control panel for testing
registers. Press and release the FCN (function) key, then press the number key of
the trigger you wish to simulate. The action of the controller will be the same as if
that trigger had been issued via P-bus.
Содержание TDC-100B
Страница 28: ...28 Notes...