GPI INPUTS (DISABLED/ENABLED)
Enables the (5) GPI Inputs available on the ‘RS-232/GPI’ connector on the rear
panel of the rack frame. These GPI inputs have the following functions:
GPI 0 - Stop
GPI 1 - Play
GPI 2 - Recue
GPI 3 - Recall Register 000
GPI 4 - Recall Register 001
27
GPI OUTPUTS (DISABLED/ENABLED)
Enables the (5) GPI Outputs available on the RS-232/GPI connector. The GPI
outputs are triggered when the TDC exits a multi-loop and begins playing the roll-out
(or tail) of a multi-loop animation. These GPI outputs have the following functions:
GPI Out 0 - Triggered when Channel A exits a Multi-loop
GPI Out 1 - Triggered when Channel B exits a Multi-loop
GPI Out 2 - Triggered when Channel C exits a Multi-loop
GPI Out 3 - Triggered when Channel D exits a Multi-loop
GPI Out 4 - Triggered when any of the four channels exits a Multi-loop
28
GPI OUTPUTS ACTIVE (LOW/HIGH)
Selects the polarity of the GPI outputs. If item is set to LOW, the outputs will rest
high, and will be pulled low when triggered. If item is set to HIGH, they will rest low
and will be pulled high when triggered. This item is generally set to LOW.
29
SWITCHER TYPE (GVG / SONY)
Selects type of production switcher TDC-100B is used with. Affects the trigger
function numbers (swaps functions 0 and 1. See page 15)
30
P-BUS PARITY (NONE/ODD/EVEN)
Sets parity mode of P-bus port. Should be set to match production switcher. Baud
Rate is always 38.4K
31
PBUS DATA DISPLAY (OFF/ON)
Turning this item on enables a display of received Pbus commands on the TDC’s
display, to assist in troubleshooting Pbus problems.