PAGE 2
MODEL NO.
JOB SPECIFICATIONS
MODEL
MINERAL TANK
-
PART NO., dia.”x ht.”
PART ID, MINERAL
(BAG qty.)
7-LXDAN-1B
FG1047DVT, 10x47
A8021, CALCITE (2)
7-LXDAN-1.5B
FG1054DVT, 10x54
A8021, CALCITE (3)
7-LXDAN-2B
FG1348DVT, 13x48
A8021, CALCITE (4)
7-LXDAN-3B
FG1365DVT, 13x65
A8021, CALCITE (6)
7-LXIM-1B
FG1044VT, 10x44
A8007, BIRM (1)
7-LXIM-2B
FG1348VT, 13x48
A8007, BIRM (2)
7-LXIM-3B
FG1465VT, 14x65
A8007, BIRM (3)
7-LXCT-1B
FG1044VT, 10x44
A8009, CARBON (1)
7-LXCT-2B
FG1348VT, 13x48
A8009, CARBON (2)
7-LXCT-3B
FG1465VT, 14x65
A8009, CARBON (3)
7-LXST-1B
FG1044VT, 10x44
A8014, FILTER AG (1)
7-LXST-2B
FG1348VT, 13x48
A8014, FILTER AG (2)
INSTALLATION DATE
SERIAL NUMBER
INSTALLER NAME
PHONE
ADDRESS
TABLE OF CONTENTS
Job Specifications ........................................................................................................................................................
2
Components ................................................................................................................................................................
2
Pre-Installation Review ................................................................................................................................................
3
General Installation and Service Warnings .................................................................................................................
3
Bypass Valve Operation .............................................................................................................................................. 4
General Installation Instructions .................................................................................................................................. 5
Installation and Start-Up for 7-LXCT, 7-LXDAN, 7-LXIM, 7-LXST ............................................................................... 6,7
Installation and Start-Up for 7-LXCTAIR, 7-LXIMAIR, 7-LXKATAIR ............................................................................ 8,9
Installation and Start-Up for 7-LXKATAIRO3 ............................................................................................................... 10,11
General Operation ....................................................................................................................................................... 12,13
User Displays
Regeneration Mode
Manual Regeneration
Service Call Reminder
Error Message
Low Battery
Set Time of Day ...........................................................................................................................................................
13
Adjust Days Between Backwash or Time of Backwash ............................................................................................... 14
Installer Contact Screen Programming ........................................................................................................................ 15
Parts Diagrams ............................................................................................................................................................ 16-25
Service Instructions
.....................................................................................................................................................26-29
Specifications ..............................................................................................................................................................30-33
Troubleshooting ...........................................................................................................................................................34-37
COMPONENTS
MODEL
MINERAL TANK
-
PART NO., dia.”x ht.”
PART ID, MINERAL
(BAG qty.)
7-LXST-3B
FG1465VT, 14x65
A8014, FILTER AG (3)
7-LXCTAIR-1B
FG1054VT, 10x54
A8056, (1)
7-LXCTAIR-2B
FG1465VT, 14x65
A8056, (2)
7-LXCTAIR-3B
FG1665VT, 16x65
A8056, (3)
7-LXIMAIR-1B
FG1054VT, 10x54
A8007, BIRM (1)
7-LXIMAIR-2B
FG1465VT, 14x65
A8007, BIRM (2)
7-LXIMAIR-3B
FG1665VT, 16x65
A8007, BIRM (3)
7-LXKATAIR-1B
FG1054VT, 10x54
KATLT, (1)
7-LXKATAIR-2B
FG1465VT, 14x65
KATLT, (2)
7-LXKATAIR-3B
FG1665VT, 16x65
KATLT, (3)
7-LXKATAIRO3-1B
FG1054VT, 10x54
KATLT, (1)
7-LXKATAIRO3-2B
FG1465VT, 14x65
KATLT, (2)
UNTREATED WATER TEST AT TIME OF INSTALLATION
Hardness CaCo
3
(gpg)
Iron (ppm or mg/l)
Other:
pH
TDS (ppm or mg/l)
CATALYTIC
CARBON
CATALYTIC
CARBON
CATALYTIC
CARBON
KATALOX
LIGHT
KATALOX
LIGHT
KATALOX
LIGHT
KATALOX
LIGHT
KATALOX
LIGHT
Содержание 7-LXDAN-1B
Страница 38: ...PAGE 38...
Страница 39: ...PAGE 39...