TITAN
80
EN
cod. 3541Z410 - Rev 01 - 09/2022
Reach the screen shown in fig. 11, navigating in the
menu and following the path "USER MENU
“Set-
tings”
"Time Setting". Press navigation buttons 5
and 7 to select the value and modify it with contextual
buttons 1 and 2. Confirm with the OK button.
fig. 11- Time Adjustment
Boiler shutdown
From the main screen/Home, press the contextual bu-
tton
and confirm with the button
.
When the boiler is turned off, the PCB is still powered.
Domestic hot water (with optional hot water tank insta-
lled) and heating operation are disabled. The frost pro-
tection system remains on.
To relight the boiler, press the contextual button again
.
The boiler will be immediately ready to operate whe-
never domestic hot water is drawn (with optional hot
water tank installed) or in case of a room thermostat
request.
To completely disconnect the unit from the power su-
pply, press the button detail 14 fig. 1.
fig. 12- Turning the boiler off
B
The frost protection system does not work when the power and/or gas to the unit
are turned off. To avoid damage caused by freezing during long shutdowns in win-
ter, it is advisable to drain all water from the boiler, the DHW circuit and the heating
system water; or drain just the DHW circuit and add a suitable antifreeze to the
heating system, as prescribed in sec. 2.3.
to confirm
Set time
15
: 59
to select
5
7
1
2
Thursday 9 Jan. 2014 00:15:60