TITAN
78
EN
cod. 3541Z410 - Rev 01 - 09/2022
Exclude hot water tank (economy)
Hot water tank temperature maintaining/heating can
be excluded by the user. If excluded, domestic hot
water will not be delivered. The hot water tank can be
deactivated by the user (ECO mode) by pressing the
eco/comfort
button (detail 10 - fig. 1). In ECO mode
the display activates the symbol
. To activate
COMFORT mode, press the
eco/comfort
button (de-
tail 10 - fig. 1) again.
fig. 7- Economy
Information
From the main screen (Home - detail
A
of fig. 8), press contextual button
2
. Access the screen for choosing the module
with information to view.
Select the module using buttons 5 and 7 (detail
B
and
C
of fig. 8) and then press
OK
.
fig. 8
Then use the "Menu Navigation" buttons to display the following values:
Thursday 9 Jan. 2014 11:30:43
23°C
32°C
1
Heating demand
OT - OpenTherm control request
TA - Room thermostat request
0-10Vdc - 0-10Vdc signal request
TA2 - Second room thermostat request
2
Heating circulating pump
ON/OFF
3
Heating 3-way valve
ON/OFF
4
DHW 3-way valve
ON/OFF
5
Standby time
ON/OFF
6
T Delta protection
ON/OFF
7
Flame Supervisor
ON/OFF
8
Heating sensor 1 (Flow)
°C
9
Heating sensor 2 (Safety)
°C
10
Return sensor
°C
11
DHW sensor
°C
12
External probe
°C
13
Fume sensor
°C
14
Cascade heating sensor
°C
15
Fan frequency
Hz
16
Burner load
%
17
System water pressure
1.4bar = ON, 0.0 bar = OFF
18
Modulating circulating pump
%
19
Cascade modulating circulating pump
%
20
Ionization current
uA
21
Input 0-10Vdc
Vdc
22
Heating adjustment temperature
Setpoint (°C)
23
Power level adjustment 0-10Vdc
Setpoint (%)
Burner controller
5
03
01
04
02
v. 04
v. 04
v. 04
v. 04
to confirm
Burner controller
07
05
08
06
v. 04
v. 04
v. 04
v. 04
to confirm