TITAN
121
EN
cod. 3541Z410 - Rev 01 - 09/2022
fig. 90
Module maintenance
The modular structure of &#Prodotto allows maintenance or replacement of parts to be carried out on the individual in-
ternal modules independently of each other.
Disconnect the unit from the power supply and close the gas cock (ref. 106 - fig. 91) of the module undergoing mainte-
nance. If necessary, drain the hydraulic circuit by connecting the hose connector pre-installed in the first module, using
a suitable rubber hose (not supplied), to a drain or a collection manifold, on the side outlet of the three-way cock (ref.
PR 1505PR 150 - fig. 91) located on the module return. Close the three-way cock (ref. PR 1505PR 150) on the return
in order to drain.
Once the maintenance operations have been carried out, proceed in reverse order, returning the three-way return cock
(ref. PR 1505PR 150) to the "open" position.
A
IMPORTANT: At the end of the maintenance operations, before turning the unit on again, check that
all the module shutoff cocks are in the "open" position.