background image

EN

10

to verify if this is actually matching our 
suggested ranges. 
Once the test has been performed, 
learn which treatment system is most 
appropriate for your particular water supply 

by  filling  out  the  online  water  calculator 

on our website: LA MARZOCCO WATER 
CALCULATOR (http://www.lamarzocco.
com/water_calculator/).

2) Connect espresso machine to power supply. 

Connect the espresso machine to a power 
supply that is rated in accordance with the 
serial plate on the espresso machine.

3) Filling the boilers with water. 

Complete the following steps to properly 

fill the boiler tanks: 

Steam boiler:

 Turn the main switch to 

position “1”, the steam boiler will then 

automatically  fill  to  a  predetermined 

level. When the correct water level in the 
steam boiler is reached, the machine will 

automatically stop filling.

NOTE: It may be necessary to re-fill the water 

reservoir during this process. 

Integrated brew group:

  The  water  flows 

inside the Integrated brew group directly 
when the water pump is activated. When 
the linea mini is turned on the electronics 

will  activate  the  water  pump  to  fill  both 

boilers. 

4) Verify filling of boilers. 

The installation is now complete and the 
espresso machine should be heating to the 
operating temperatures.

Brewing after first installation

Once  the  first  installation  procedures  are 
finished,  before  proceeding  with  brewing 

coffee, hot water and steam, please follow 
these steps:

• Engage the portafilter by inserting it into 

the group head and rotate the handle from 

left to right. Once the portafilter is inserted 

properly, you can move the paddle on the 

left side to start the flow of water through 
the  portafilter.  Brew  water  through  the 

group for at least two minutes.

•  Being  careful  to  avoid  burns,  turn  on 

steam wand for at least one minute.

• Turn on the hot water valve for the time 

necessary to allow at least 1 liter of 
water to be brewed.

5) Waiting for the espresso machine to heat to 

operating temperature. 

During this time, the pointer of the 
Integrated brew group pressure gauge may 
reach as high as 12 bar. This may happen 
anytime that the heating element is in the 
“on” condition. If the pressure exceeds 12 
bar then it will be necessary to adjust the 
expansion valve in such a manner that the 
pressure never exceeds 12 bar.
In normal operating conditions, the 
Integrated brew group pressure gauge 
can read anywhere from 0-12 bar. When 
brewing, the pressure should be set to 
approximately 9 bar.
The machine is ready to brew water when 
the power indicator light (red) is ON.
When the machine is warming up the 

power indicator light (red) is flashing.

 

NOTE: As the steam boiler reaches operating 
temperature you may hear air and steam 
escaping from the boiler. This is a normal sound. 

As the water boils, air in the boiler is replaced by 
steam and exits through the vacuum breaker. As 
the boiler get closer to operating temperature 

the vacuum breaker closes and the steam is 
no longer able to escape. This process allows 
the air in the steam boiler to escape and to be 

replaced by water vapor.

Содержание linea mini

Страница 1: ...e for the home reflecting the classic iconic design in a miniature version The linea mini with its stainless steel group for coffee and a boiler for steam and hot water is prepared to brew quality sho...

Страница 2: ...F 39 055 849 1990 Chapters 1 Important Safeguards 2 General Information 3 Machine Description 4 Installation 5 Operation 6 Key Features 7 Preventative Maintenance and Cleaning 8 Installation Guide 9 T...

Страница 3: ...and before cleaning the appliance 6 Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions or has been damaged in any manner Return appliance to the nearest auth...

Страница 4: ...al capabilities or lack of experience and knowledge as long as they have been given supervision by a person responsible for their safety and if they understand dangers Children should be supervised to...

Страница 5: ...parts have been connected improperly WARNING Hazardous voltage disconnect from power supply before servicing WARNING The machine must be installed so that qualified technical personnel can easily acc...

Страница 6: ...ich the manufacturer shall not be held responsible 4 Safe electrical operation of this device will be achieved only when the connection to the power outlet has been completed correctly and in observan...

Страница 7: ...id dangerous overheating problems it is recommended that the power supply cable be unfurled completely 12 Do not obstruct air intake and exhaust grilles and in particular do not cover the cup warmer t...

Страница 8: ...addle Group cover Cup tray Main power switch Pressure gauge steam boiler Steam wand Hot water activation knob Hot water dispensing spout Drain box Group head Pressure gauge integrated brew group Steam...

Страница 9: ...nd the quantity of chlorides be less than 50mg l Respecting these values allows the machine to operate at maximum efficiency If these parameters are not present a specific filtration device should be...

Страница 10: ...steps Engage the portafilter by inserting it into the group head and rotate the handle from left to right Once the portafilter is inserted properly you can move the paddle on the left side to start th...

Страница 11: ...ed brew group causes the water within to expand Since the integrated brew group is completely saturated the expanding water causes an increase in pressure within the boiler Without a safety device the...

Страница 12: ...wer tray 2 Locate the water pump adjustment screw and loosen the lock nut 3 Adjust the water pump pressure to the desired measurement 4 Rotate clockwise to increase pressure and counter clockwise to r...

Страница 13: ...er on the linea mini Move the paddle handle from right to left to begin brewing see Fig 1 page 8 Note Some users believe it is important to allow water to pass through the integrated brew group prior...

Страница 14: ...et NOTE It is important to have a sufficient volume of liquid in the steaming pitcher Therefore if you intend to steam small amounts of milk it is necessary to use a small pitcher If you intend to ste...

Страница 15: ...owly drop by drop nor too quickly A general rule is that a double dose should dispense approximately 60ml 2 fluid oz of espresso in approximately 25 seconds This time may be adjusted by varying the co...

Страница 16: ...p several times until you notice clear water being released instead of soapy water when you remove the portafilter Do not remove the portafilter when group is dispensing water Rinse the group using a...

Страница 17: ...tip clean Repeat process if residue remains 5 Cleaning the hot water nozzles Hot water nozzles must be cleaned periodically with a damp cloth soaked in water and or mild soap NOTE This cleaning schedu...

Страница 18: ...wer 6 Monitor integrated brew group pressure 7 Adjust the expansion valve 8 Monitor steam boiler pressure 9 Brew espresso 10 Verify working boiler pressures 11 Integrated brew group temperature 12 Ste...

Страница 19: ...d water Slide the reservoir back into position and replace the drain box Make sure the drain box is inserted fully The water reservoir must make contact with the level indicators on the rear side NOTE...

Страница 20: ...ment grooves It may be necessary to push slightly on the front of the drain box to achieve proper alignment When the machine is ON and the water tank is full the water reservoir indicator light blue i...

Страница 21: ...ar of the machine 5 WARNING The manufacturer declines any responsibility for any event leading to liability suits whenever grounding has not been completed according to current local national and inte...

Страница 22: ...t the maximum pressure in the integrated brew group to 12 bar Please monitor the integrated brew group pressure gauge during the initial heating process You should notice the gauge approach 12 bar and...

Страница 23: ...expansion valve rotate the valve clockwise to raise the pressure and counter clockwise to reduce the pressure It may be necessary to use a spanner to rotate the expansion valve in 1 4 turn or less inc...

Страница 24: ...ress by watching the steam boiler pressure gauge The steam boiler is set at approximately 2 0 Bar of pressure at the factory Once the pressure gauge reaches this point the heating will stop 8 Steam bo...

Страница 25: ...ortafilter and activate the brewing process When brewing the integrated brew group pressure should be between 8 10 bar The steam boiler pressure should be set at 2 bar but can operate at any setting b...

Страница 26: ...egrated brew group is held constant by means of the mass of the group casting Even though the temperature of the water may vary slightly the temperature of the water exiting the group is constant To p...

Страница 27: ...t Little coffee in the filter Excessively coarse grind The coffee was insufficiently pressed Stale or unsuitable coffee Check the millstones of the coffee grinder for wear Contact the service departme...

Страница 28: ......

Отзывы: