2FT
1-6-24
5. Remove the screw holding each of the front
and rear wire retainers and then remove the
mirror 1 frame from the scanner unit.
Figure 1-6-43
6. Unhook the round terminal of the scanner
wire from the scanner tension spring on the
left side of the scanner unit.
7. Remove the scanner wire.
Figure 1-6-44
Mirror 1 frame
Rear wire
retainer
Front wire
retainer
Scanner tension springs